Operation; Laser - MAHLE Digital ADAS 2.0 Manual De Instrucciones

Ocultar thumbs Ver también para Digital ADAS 2.0:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 149

6. Operation

The calibration procedures of the Digital ADAS
2.0 system are guided by the scantool instru-
ment.
6.1
DLM-01 Laser
There are two intended modes of use for the
DLM-01:
Measurements with DLM-01 on measuring
bar
In this mode, the DLM-01 is installed on the spe-
cific support located on the measuring bar in the
Digital ADAS 2.0. It is used to take measure-
ments to determine the position of the vehicle
in calibration with respect to the structure or a
single component (e.g. RADAR module)
Measurements taken are:
Distance in mm from the reference target
n
placed on the clips mounted on the vehi-
cle's tires or from the specific component
(e.g. RADAR module). This measurement is
taken with the LASER meter
Position in mm of the DLM-01 on the mea-
n
suring bar, with respect to the origin point
(end of the measuring bar).
Measurements with DLM-01 outside the
measuring bar
In this mode, the DLM-01 is detached from the
mount and used to take specific measurements
on the vehicle.
Measurements taken are:
Distance in mm from the rear side of the
n
LASER meter to the required point (e.g.:
wheel arch height from the ground)
This measurement is taken with LASER
n
distance meter