Micropulse Transducer - Rod Style
6
Configuration with the Micropulse Configuration Tool (continued)
Freely configurable curve
Null and end points can be read (teach-in) or specified
with the mouse.
The distance between the null point and end point
must be at least 4 mm.
The characteristic curve can be inverted or copied from
the other output.
The limits can be adjusted to the measuring range.
The error value can be set in accordance with the
limits.
Boundary conditions for two magnets
Two magnets can only be selected if the nominal length
is ≥ 90 mm.
The distance between two magnets must be ≥ 65 mm.
Locking the calibration device
The function to manually adjust the transducer with the
calibration device can be locked, making configuration only
possible with the PC software.
Uncontrolled system movement
When starting up, if the position measuring system is part
of a closed loop system whose parameters have not yet
been set, the system may perform uncontrolled
movements. This could result in personal injury and
equipment damage.
► The system must be taken out of operation before
configuration.
► Transducers may only be connected to the
communication box for configuration.
► The communication box must be removed after
configuration.
16
english
DANGER
Ignition protection
"nA" and "tb"