Specifi cations
Compatibility
I/O
Trigger
Inputs
Outputs
High Speed
Outputs
CC-Link
Connectors
Ethernet (LAN)
PoE
Serial (RS-232)
I/O
Electrical
Current
Voltage
Power
Consumption
Environmental
Temperature
In-Sight Micro and 5600 series vision systems
Optically isolated trigger input;
ON: 20 to 28V (24V nominal), < 7.5mA;
OFF: 0 to 3V (8V nominal threshold), < 250μA; Resistance ~10,000 Ohms
8 general purpose, optically isolated discrete (Maximum 30VDC, 10.4 mA)
8 general purpose, optically isolated discrete (Maximum 30VDC, 100 mA)
In-Sight Micro: 2 optically isolated discrete (Maximum 28VDC, 100 mA)
In-Sight 5600 series: 2 discrete (Maximum 28VDC, 200 mA)
CIO-MICRO-CC only. Standard CC-Link terminal connectors. See the
CC-Link specifi cations for more information.
RJ-45 10/100 port (IEEE 802.3 Type 10Base-T; IEEE 802.3u Type
100Base-TX; IEEE 802.3ab 100Base-T Ethernet)
RJ-45 10/100 port (IEEE 802.3 Type 10Base-T; IEEE 802.3u Type
100Base-TX; IEEE 802.3ab 100Base-T Ethernet) with PoE
1 RS-232C port (4800 to 115,200 baud), 8 data bits, 1 stop bit, RxD, TxD,
and fl ow control (RTS/CTS & XON/XOFF)
In-Sight Micro: DB15 I/O providing Trigger, HS OUT 0, HS OUT 1 and
HS COMMON signals.
In-Sight 5600 series: DB15 I/O providing Trigger, HS OUT 0 and
HS OUT 1 signals, 24VDC and ground.
600mA (maximum)
24V +/- 10%
14.4W (maximum)
Operating: 0°C to 45°C (32°F to 113°F)
Storage: -10°C to 65°C (14°F to 149°F)
9