Installation
The installation steps in this document describe how to connect the CIO-MICRO or
CIO-MICRO-CC I/O module to an In-Sight Micro vision system. If connecting an
In-Sight 5600 series vision system to the CIO-MICRO or CIO-MICRO-CC I/O module,
refer to the In-Sight
Manual for detailed installation steps. The manual is installed with In-Sight Explorer
4.3.0 and higher software. From the Windows Start menu, select the following to
access the manual: All Programs > Cognex > In-Sight > In-Sight Explorer x.x.x >
Documentation.
Note: Cables are sold separately. If any of the contents appear to be missing or
damaged, immediately contact your Cognex Authorized Service Provider (ASP) or
Cognex Technical Support.
1
Connect the Power Wires
Caution: Never connect the I/O module to a power source other than
24VDC. Any other voltage creates a risk of fi re or shock and can damage the
hardware. Do not connect the 24VDC power source to any terminals other
than the 24VDC + and – power connectors.
1.
Verify that the 24VDC power supply being used is unplugged and not
receiving power.
2.
Use a screw driver to loosen the power terminals (labeled 24VDC +
and –).
3.
Insert the 24VDC + and – wires (16 - 22 AWG, solid or stranded wire)
from the power supply into the 24VDC + and – terminals on the I/O
module.
4.
Tighten the screw terminals with the screwdriver to secure the wire leads
in the terminal block; the maximum torque is 0.1921 Nm (1.7 in-lb).
®