Connect the CC-Link Wires
If connecting the vision system to a CC-Link device, complete the following
steps.
Note: The CC-Link terminals are only available on the CIO-MICRO-CC
I/O module.
1.
Determine how CC-Link devices will be connected to the I/O module's
CC-Link terminals.
2.
Use a screw driver to loosen the appropriate screw terminals.
3.
Connect the CC-Link wires (using a CC-Link specifi ed cable) to the
CC-Link terminals and the other end of the cables to the applicable
CC-Link devices.
4.
To reduce emissions, attach a Steward 28A0640-0A2 ferrite around the
CC-Link wire bundle, as close to the connector as possible.
Note: The CC-Link network is daisy-chained and requires a terminal
resistor for the fi rst and last devices in the chain. Make certain that
your connections are correct. Refer to the CC-Link web site for more
information and specifi cation details.
5.
Tighten the screw terminals with the screwdriver to secure the wire leads
in the terminal block; the maximum torque is 0.1921 Nm (1.7 in-lb).
5
Connect an RS-232 Serial Cable
If connecting the vision system to a serial device, plug an RS-232 serial cable
(DB9 connector) into the I/O module's RS-232 port and connect the other end
of the cable to the serial device. Tighten the connector screws to secure it to
the I/O module.