The maximum torque that can be applied to the terminal block connectors
is 0.1921 Nm (1.7 in-lb). Applying torque above this limit can damage the
connectors.
The I/O module does not contain user-serviceable parts. Do not make any
electrical or mechanical modifi cations. Unauthorized modifi cations may void your
warranty.
Changes or modifi cations not expressly approved by the party responsible for
regulatory compliance could void the user's authority to operate the equipment.
The I/O module is intended for indoor use only.
The I/O module supports In-Sight 5600 series vision systems. When using an
In-Sight 5600 series vision system, the vision system's Ethernet cable must
be connected to the I/O module's PoE port and its I/O Module cable must be
connected to the I/O port.
Access to the encoder inputs on the In-Sight 5604 (Line Scan) is not supported
by the I/O module.
HS COMMON is not used for high-speed outputs with In-Sight 5600 series vision
systems. The return must use –24VDC.
Cable shielding can be degraded or cables can be damaged or wear out more
quickly if a bend radius or service loop is tighter than 10X the cable diameter.
Service loops should be included with all cable connections.