GB
V
steps described above in the reverse order.
! Take particular care when handling the spark plug wires and the
thermocouple pipes.
• Primary air regulation for the oven burner
The burner was designed not to need any adjustments to the primary air.
• Setting the oven burner to minimum
1. Turn the knob first to the Max setting for about 10 minutes and then to
Min.
2. Remove the knob.
3. Remove the disk fastened to the control panel.
4. Adjust the screw located outside the thermostat cock pin until the flame
is small but steady (the flame can be seen through the slots on the oven
bottom).
fastened as tightly as possible.
10
All manuals and user guides at all-guides.com
2. Slide out the bottom of the oven.
3. Unscrew the burner fastening screws.
4. Remove screw "V" and then the
oven burner.
5. Unscrew the oven burner nozzle
using the special socket spanner for
the nozzles, or better still a 7 mm
socket spanner, and replace it with a
nozzle suited to the new type of gas
(see Table 1).
6. Replace all the parts, following the
5. Make sure the burner does not switch
off when you turn the knob from Max
to Min quickly, or when you open and
close the oven door quickly.
! If the appliance is connected to liquid
gas, the regulation screw must be
! Once this procedure is finished, replace the old rating sticker with one
indicating the new type of gas used. This sticker is available from any of our
Service Centres.
! If the gas pressure is different from the recommended pressure, a suitable
pressure regulator must be fitted to the inlet pipe in accordance with current
National Regulations.
DATA PLATE
width 43.5 cm
Dimensions
height 31 cm
depth 43.5 cm
Volume
58 l
Electrical
see data plate
connections
Gas features
see data plate
This appliance conforms to the
following European Economic
Community directives:
2006/95/EEC dated 12/12/06
(Low Voltage) and subsequent
amendments - 2004/108/EEC
dated 15/12/04 (Electromagnetic
compatibility) and subsequent
amendments - 93/68/EEC dated
22/07/93 and subsequent
amendments. 2009/142/EEC
dated 30/11/09 (Gas) and
subsequent amendments.
2012/19/EC and subsequent
amendments.