Troubleshooting

WARNING!
All the following special maintenance operations shall be carried out by a service mechanic.
FAULT
Mechanical head overheating. Dirt and/or wear and tear of the
Anomalous rake (2) vibrations. • Rotating parts wear and tear.
The tool does not work.
The
tool
is
not
powerful
enough.
Temporary tool stopping dur-
ing its use.
IMPORTANT: If the above-mentioned remedies do not solve the problem, contact an Authorised Service Point

Improper uses

-
Never use the tool when your balance is unstable.
-
Never use the tool as a lever or for lifting, moving or breaking any objects.
-
Never use the tool if the atmosphere is explosive or inflammable.

Tool transport

In case of long transports keep the tool in its packaging.
WARNING!
Use the tool only for the purposes described in par. "Product Description". Any other use can cause injuries
and damages.

Routine maintenance

WARNING!
Before any routine maintenance operations, if the harvesting head is assembled on the tool, switch the
harvester off (read the power unit manual), disconnect the power supply cable and then remove the head
from the extension pole (11-12).
All maintenance operations which are not described in this manual shall be carried out only by an Authorised
Service Point.
Routine maintenance operations can be carried out by the operators.

General

Before any routine maintenance operation:
Select the OFF mode of the power unit switch.
Wear protective gloves.
Disconnect the harvesting head from the extension pole (11-12).

Replacing the teeth

The damaged teeth (1) have to be removed from their seat:
Disassemble the teeth holder (7) by removing the 4 screws (6).
Put the teeth holder (7) onto a surface and shorten the damaged teeth (1) 2 cm away from the holder.
By means of a rubber hammer hit the top of the tooth (1) till it gets out of its seat.
Put the new tooth (1) into its seat, being careful to hook the small plastic protrusion to the teeth holder (7) side.
Re-assemble the rake (2) onto the oscillator (8).

Cleaning and greasing the harvesting head

Every 200 work hours, open the mechanical head and remove any dust and dirt inside of it. Check the anti-rotation
drives (10) condition and add Campagnola LISYNT-00-EP spray grease.
Pag. 20
CAUSE
inner rotating parts.
• Wrong tightening of the rake
fixing screws (6).
Flat battery.
Falt battery.
• Motor overheating due to
thick branches.
Exceeded current limits
REMEDY
Carry out the mechanical head cleaning and
maintenance operations.
• Carry out the mechanical head cleaning and
maintenance operations.
• Tighten the screws (6).
Recharge the battery (read the power unit manual).
Recharge the battery (read the power unit manual).
Get out of the tree, wait for few seconds and then
start the tool again by means of the ON-OFF
switch (read the power unit manual).
Use and maintenance manual – Translation of