6.2
Fault fl ow chart, English
Fault fl ow chart
Default settings when using the Fault fl ow chart
How to use the Fault fl ow chart
PLASMA
DISPLAY PANEL
(PDP)
No picture
PDP st.by LED = No Light
120 V AV at M60P448
- Press TV on Beo4
- Select a TV channel with picture and sound
NO
YES
Reference to a measuring point is marked:
See page 6.8 and 6.9 for placement of measuring points.
Check
F900 & F901
defective fuse
OK?
2
Confirm voltage
Module P
P23p2 15.3±0.5
P25p1 15.3±0.5
P25p5 13.3±0.5
P25p7 5.2±0.3
P27p4 5.0±0.3
All OK?
3
YES
Replace
Replace
Module P
3
NO