Assembly Instructions 626-627 - Teuco 626 Instrucciones De Montaje

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 20
INSTRUCTIONS FOR INSTALLATION Art. 626-627
The product must be installed exactly as supplied by Teuco, otherwise the warranty will be invalidated.
The directions for installation must be observed to the letter, as must those concerning recommended materials and the accessories
supplied with the product.
Electrical connections must be carried out in compliance with national safety regulations, as indicated in the preinstallation data sheet.
This manual constitutes an integral part of the product and must be kept for future reference.
Data and specifications indicated are not binding to the company: Teuco Guzzini SpA reserves the right to make such changes as are
deemed appropriate without prior notice and without any obligation to update.
This product is intended for home use. In the event of a Teuco minipool being commissioned for public use, procurement managers
must ensure compliance with all statutory regulations governing safety, water treatment and utility systems normally in force in the
country of installation.
3
OPENING THE PACKING
Remove the crate and packing, leaving the minipool on the pallet.
Whatever transport and handling operations are involved, use only
the pallet on which the minipool is packed for shipment.
4
REMOVING THE COVER
Remove the cover (art. 627 only: unhook the retaining straps at the four
corners).
The cover is not intended to carry weights.
Do not sit, step or lie on the cover.
Do not place objects on the cover.
The canvas can be dangerous if not secured or properly closed.
Failure to follow the instructions for securing the canvas can result
in danger to the user.
Remove the canvas completely before stepping into the pool,
otherwise there is a risk of being trapped.
5a
REMOVING THE PROFILES
Remove the protective profiles located between the panelling and the
edge of the minipool.
5b
REMOVING WOOD PANELS
Unscrew the screws (A) at the base of the panels and pull the panels
towards you (B) so that they come away from their seating.
Lift the panel until the top sections are released (C) then remove each
panel from the structure securing it in place in numerical order.
6
A
FITTING THE LIFTING BARS
Insert the lifting bars into the sides of the frame and secure them with
the special screws and nuts.
NEVER LIFT THE MINIPOOL BY THE RIM OR BY THE PIPELINES.
THE MINIPOOL MUST NEVER BE LIFTED WHEN FULL OF WATER.
6
B
PLACEMENT
When lifting and placing the minipool, use slings of suitable load
capacity at least 4 metres in length (distance from the bars on the
minipool frame to the lift hook).
Slip the slings over the bars (B) and proceed to lift the minipool, then
place it on the selected site (the weight of the minipool when empty is
approximately 350 kg).
Remove the bars (B) and keep handy for future use, if needed.
7
PLUMBING CONNECTIONS
DRAIN CONNECTION
The Teuco minipool has a gate type drain valve with a
ø 40 mm connection.
Connect the valve to the main drain by way of a trap (see preinstallation
data sheet - step 2).
WARNINGS
FILL CONNECTION
The recommended method of filling the Teuco minipool is to use a hose
(taking care not to immerse the end as this could cause a reflux of water
back into the main).
8
HEAT EXCHANGER CONNECTIONS
The minipool is provided with a switch box (M) containing a relay with a
"normally open voltage-free" contact (3A Max - spare terminals
connected to Black and White conductors) that can be used as an
on/off switch control for a boiler, a recirculation pump, a zone valve or
other appliance/component. The electrical connection to the box must
be permanent, able to handle the rated current, and specified to liquids
ingress protection category IPX5. Install the pipes (C and C1) carrying
water to and from the boiler as indicated.
HEAT EXCHANGER SPECIFICATIONS
Minimum output of boiler
Maximum flow of recirculation pump (P)
Minimum head of recirculation pump (P)
Max water temperature in boiler
Boiler pipe connections
9
ELECTRICAL CONNECTIONS
Make the connection to the A.C. power supply at the terminal box (D)
provided on the minipool.
Electrical connections must be made in compliance with safety
regulations, as indicated in the preinstallation data sheet (step 2).
The size of the power cable and the relative clamp must be selected
according to the current load, the distance from the junction box and the
way the cable is laid and routed.
The jobs of drilling the terminal box and selecting and fitting the IPX5
clamp are the responsibility of the installer.
Having made all the connections, check that the system operates
correctly (see user manual - STARTING UP FIRST TIME).
CAUTION: POWER UP THE ELECTRICAL EQUIPMENT ONLY
AFTER THE MINIPOOL HAS BEEN FILLED WITH WATER.
10
FITTING WOOD PANELS (Art. 627)
Hook the top part of the panel into the special hooks on the frame (A).
Place the panels below the rim of the minipool (B).
Fix the panels to the minipool using the special screws supplied (C).
Fit the panels in numerical order.
11
FITTING THE PROFILES
Insert the protective profiles between the panelling and the edge of the minipool.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1600 l/h
. . . . . . . . . . . . . . . . . . .
1.8 m.c.a.
. . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
GB
7 Kw
80°C
3/4"
15

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

627

Tabla de contenido