INSTALL THE FILTERS
1. To install the grease fi lters, align rear fi lter tabs
with slots in the hood. Push latch tab in, push
fi lter into position and release. Make sure fi lter
is securely engaged after installation. Fig. 16.
2. To remove the fi lters for cleaning, push latch
tab in to disengage fi lter from hood. Tilt the
fi lter downward and remove.
NOTE: Remove protective fi lm from fi lters and
steel surfaces before using cooking under
range hood.
PROGRAMMING MODE
PROCEDURE
The range hood is designed to work with
several diff erent blower models. Before
us-ing, the control must fi rst be programmed
to your blower model, in order to achieve
proper operating speeds.
From the chart below:
1. Find the SETUP number that corresponds
to the blower model that is installed with
your range hood.
2. The control is factory-preset to SETUP 3.
If your blower model is listed under SETUP
3, no programming is required. The range
hood is ready to use.
SETUP 1
EB6
BLOWER
MODEL
ILB3
NUMBER
ILB6
SETUP 2
SETUP 3(default)
EB12
EB9
EB15
ILB11
ILB9
- 15 -
3. For blower models listed under SETUP 1
or 2 follow this program sequence:
A - Power at the service box must be
ON while programming. The blower and
lights must be turned off .
B - Press P2 for 3 seconds. The L1
LED ring will fl ash at 3 diff erent rates of
speed: slow fl ashing speed = SETUP
1; medium fl ashing speed = SETUP 2;
fastest fl ashing speed = SETUP 3 (the
factory-preset default).
C - To select the proper SETUP, press
P3 (-) or P4 (+) to change to SETUP 1,
2 or 3.
D - Once the proper SETUP is found,
press P2 (f ) to memorize the SETUP
setting.
E - The range hood is now ready to use.
FIG. 16