It is the responsibility of the installer/owner to ascer-
tain compliance with specific local regulations prior to
installation.
Jacuzzi Europe S.p.A. gives no guarantee in this re-
spect and refuses all responsibility regarding compli-
ance of the installation carried out.
Technical Features
The Premium spas feature a single-phase power supply (220-
240 V). All electro-mechanical parts and pipes are enclosed.
The models of the J-400 range have 1-2-3 hydromassage
pumps and a circulation pump.
Maximum absorption of the system
Power supply
(single-phase)
Voltage
Hertz
J-415
220-240 ~
50
50
J-465
220-240 ~
50
J-480
220-240 ~
50
220-240 ~
J-495
The electrical system that powers the spa must absolutely
be sized for maximum consumption (as shown in the table).
Weights
net weight
average fill
kg
litres
~ 765
J-415
~ 263
J-465
~ 370
~ 1438
~ 431
~ 1817
J-480
~ 500
~ 1968
J-495
area involved
support area
m
2
J-415
~ 3,23
~ 3,1
J-465
~ 5,01
~ 4,4
J-480
~ 5,71
~ 5,4
~ 6,38
~ 6,2
J-495
(k): 230 V
pump(s)
electric
(single-phase)
heater
Ampere/kW
Ampere/kW
(j): max. power
absorption
(j)(k)
(j)(k)
17/3,8
12/2,6
(j)(k)
(j)(k)
17/3,8
12/2,6
(j)(k)
(j)(k)
17/3,8
12/2,6
(j)(k)
(j)(k)
17/3,8
12/2,6
maximum
water volume
litres
~ 1060
~ 1323
~ 1817
~ 2187
~ 2158
~ 2589
~ 2346
~ 2846
average load
load concentrated
on area involved
on support area
m
2
kg/m
2
~ 409
~ 436
~ 453
~ 446
User safety
I
The system, if installed by qualified personnel, does not present
any hazard for the user. Safety is however also contingent upon
proper use, as set forth by the user's manual included with the
product. The user must contact qualified personnel for special
operations described in the manual.
I
It is important to make sure that personnel tasked to install and
manage the system are qualified as per legal requirements in
effect in the country where installation is carried out.
I
Periodically, however, the differential switch (see "ELECTRICAL
SAFETY" chapter) of the system to which the mini-pool is con-
nected must be checked for efficiency. When you press the
TEST key, the switch must disconnect. If this does not
happen, disconnect the power supply immediately and
contact a qualified technician.
I
For any extra maintenance and/or repairs it is recommended that you
contact an Authorized Service Centre and use only original spare parts.
Set up for installation
I
Premium spas are equipped with the drain arranged as in
1-1a-1b-1c, detail A.
The customer must make provisions for a ground drainage point
of suitable dimensions and that can be inspected for any cleaning
that may be required.
ATTENTION: Before preparing the ground drainage
point, consult the local authority for the regulations
that control the drainage of chemically treated water.
I
For periodic emptying of the MaxiJacuzzi
rubber hose to the drain valve (
total max.
weight
NOTE:To open the valve, turn the ring nut counter-clockwise and pull.
kg
If you decide to attach the MaxiJacuzzi to the drain, it is advis-
able to connect upstream from the valve (for greater flow capac-
ity) and to install a shutter valve near the drain in an accessible
i
area (
I
According to the type of installation chosen the ground drainage
point will then be put into position.
installed in a variety of ways:
kg/m
2
~ 427
- Free standing on the floor or on a specifically prepared base
i
~ 497
(
4).
~ 479
~ 459
- Semi-built in, so that only the base of the spa is built-in and
therefore the side cover panels remain free (
it is appropriate to prepare some removable under-frames (in
marine plywood, etc.) that, besides aesthetically completing in-
stallation, allow the panels to be removed more easily.
I
In any case you will need to provide a support base that is suit-
able for the selected model, taking into consideration the data
contained in the table "Weights".
I
You can use a garden hose to fill the spa.
14
i
1-1a-1b-1c, detail A).
1-1a-1b-1c, detail
A1).
i
®
you can connect a
The Premium spas can be
i
5). In this case,