INSTRUCTION MANUAL (Translation from the original Spanish)
A
Warning! Observe limitations of use.
B
The name plate voltage must be the same as the
mains voltage.
C
Connect the pump to the mains via an omnipolar
switch with at least a 3mm opening between
contacts.
D
Install a high-sensitivity differential switch (0.03A)
as extra protection against lethal electric shocks.
E
Connect the pump to the ground.
F
Use
pump
only
indicated on the name plate.
G
Be careful with hazardous liquids and environments. K Cut out power supply before servicing pump.
H
Do not carry the pump by the power cable.
Contents
Safety precautions .................................................... 8
1. General information ............................................. 8
2. Handling ............................................................... 9
3. Installation ........................................................... 9
3.1. Fixing .......................................................... 9
4. Starting ................................................................ 9
5. Maintenance ........................................................ 9
7. Nameplate ......................................................... 10
10. List of main components .................................... 30
11. Illustrations......................................................... 31
Safety precautions
This symbol
following words "Danger" or "Warning" indicates the
risk level deriving from failure to observe the
prescribed safety precautions:
DANGER
Warns that failure to observe
the pre cautions involves a risk
risk of
of electric shock.
electric
shock
DANGER
Warns that failure to observe
the pre cautions involves a risk
of damage to persons and/or
things.
WARNING
Warns that failure to observe
the pre cautions involves the
risk of damaging the pump
and/or the facility.
Do not put your hand or any
object into the suction or
discharge mouth, since the
rotating impeller could cause
serious injury or damage.
Damage prevention and safety instructions
(See figure 4)
within
performance
limits
together with one of the
I This apparatus may be used by children older
than 8 and persons with reduced physical,
sensory
or
mental
experience and knowledge, if they are supervised
or receive adequate training on the safe use of the
apparatus and understand the dangers.
Children should not be allowed to play with the
apparatus.
Children should not perform the ordinary cleaning
and maintenance tasks without supervision.
J The pump should only be dismantled by
authorized personnel.
L Caution! Avoid icing.
1. GENERAL INFORMATION
Please observe the following instructions to achieve
the best pump performance possible and a trouble
free installation.
Read these instructions before installing the
pump.
Save them for future reference.
DRAIN series have been designed for the drainage
of infiltration water, empty water tanks or swimming
pools. DRAINEX series are used for the drainage of
sewage water with particles in suspension, septic
tanks, etc. The maximum water temperature is
35°C. Passage of particles up to 35mm.
All pumps have been manufactured in top quality
material, submitted to strict hydraulic and electric
controls.
Correct pump operation is assured providing
the instructions on electrical connection,
installation and use are strictly adhered to.
Failure to adhere to the instructions can
result in premature failure of the pump and
voiding of the warranty.
The pump cannot be used in a swimming-
pool while there are people bathing.
2. HANDLING
The pumps are supplied suitably packaged to pre-
vent damage in transit. Before unpacking, check
that the packaging has not been damaged or de-
formed,
Lift and handle the product with care and with
the right tools.
8
EN
capacities,
or
lacking