Chapter 5. Film features
5.1. Films to be used
The machine can work with all heat shrink and non-heat shrink films, from 15 to 50 microns in thickness, of a technical
and food type. To guarantee the best results, it is recommended to use the films marketed by us.
The special features of our films (which may be customised with drawings and text) assure their outstanding reliability,
with regard both to compliance with laws in force and to an excellent machine performance.
It is recommended to refer to the technical and safety sheets of the films in use and to observe the
corresponding instructions!
Replay 40
A = mm500 MAX
Replay 55
A = mm600 MAX
5.2. Band A calculation
Band A = b + c + 100mm (figure 5.2. page 60).
Chapter 6. Safety standards
6.1. Warnings
THE MACHINE CAN NOT BE USED BY UNTRAINED PERSONNEL!
During the work phases pay attention to all hot parts of the machine. The temperature they can
reach is so high that it can cause burns.
It is forbidden to smoke when the machine is working!
Do not touch the sealing blade (13) soon after sealing by reaching beyond the safety guard (12). Danger of burns
due to residual heat on the sealing blade (figure 6.1.A page 60).
Do not keep on sealing in case the sealing blade breaks (13). Replace it at once (figure 6.1.A page 60).
Do not touch the chamber closing flap (16) during warm-up function. Danger of burns (figure 6.1.B page 60).
Do not touch the fan while moving or using the machine without the reticulated plate (11) (figure 6.1.B page 60).
Make sure the film reel is properly lodged (14) (figure 6.1.C page 60).
Make sure the rubber feet (15) of machine are lodged in the holes of the wheeled stand (if machine is equipped with
trolley).
Every time you turn the machine off, it is recomended to leave the upper hood (19) open (figure 6.1.D
page 60).
Chapter 7. Ordinary maintenance
7.1. Precautions for ordinary maintenance interventions
ORDINARY MAINTENANCE, MUST BE EXECUTED BY QUALIFIED STAFF APPROPRIATELY TRAINED.
Before proceeding to maintenance, switch the machine off and disconnect it by operating on the
master switch and wait for the machine to cool down!
It is recommended to use protection gloves during maintenance operations!
D = mm250 MAX
D = mm250 MAX
14
d = mm77 (figure 5.1. page 60).
d = mm77 (figure 5.1. page 60).