Chapter 2. Machine installation
2.1. Transport and positioning
It is recommended to handle with great care during transport and positioning..
Use protection gloves while handling the machine.
Cut the strap with scissors (make sure you protect your eyes by wearing glasses) and withdraw the cardboard
(figure 2.1.A page 58).
Remove the cardboard containing the trolley (figure 2.1.B page 58).
Unscrew the 4 fastening screws (B) of the pallet, putting the 4 plates back inside the machine (C) (figure 2.1.B page
58).
Assemble the trolley (figure 2.1.C page 58).
Lift the machine and place it on its trolley, paying attention that the 4 supports are properly inserted in their housings.
Remove the upper hood by cutting the strings.
IF IT IS TRANSPORTED BY HAND, 4 PEOPLE ARE REQUIRED FOR ITS TRANSPORTATION.
When lifting the machine, always grip it by the ends and never by the reel support (5).
2.2. Environmental conditions
Place the machine level on the floor in a suitable environment free from humidity, gases, explosives, combustible
materials. The machine may only be installed on smooth, flat non-inflammable surfaces.
Leave a minimum space of 0,5m around the machine so that not to obstruct air inlets
Once the correct position is achieved, lock the machine by means of the wheel brakes.
Working environment conditions:
Temperature from + 5°C to + 40°C
Relative humidity from 30% to 90%, without condensation.
The lighting of the operation room shall comply with the laws in force in the country where the machine is installed.
However, it shall be uniform and allow good visibility in order to safeguard the operator's safety and health.
MACHINE PROTECTION FACTOR = IP20
THE AIRBORNE NOISE MADE BY THE MACHINE IS LOWER THAN 70 dB(A)
2.3. Electrical connections
Voltage (V): see data on plate
Frequency (Hz): see data on plate
Maximum absorbed power (W): see data on plate
Maximum absorbed current (A): see data on plate
N.B.: when contacting the Manufacturer, always indicate the model and the serial number
specified on the plate on the rear part of the machine.
OBSERVE HEALTH AND SAFETY REGULATIONS!
If the machine is not equipped with the power supply plug, use a plug that is suitable for the
voltage and amperage values described by the rating plate and that can comply with the rules
in force in the installation country.
GROUNDING OF THE UNIT IS OBLIGATORY!
Before making electrical connections, make sure the mains voltage matches the one on the
plate on machine rear and that the ground contact complies with the safety rules in force.
In case of doubts about the mains voltage, contact the local power supply company.
Insert the plug on the cable from machine electrical cabinet in a mains power supply socket
that can be reached easily by the operator.
11
EN