Io-Link Device Parameters For Pd30Etb Io-Link; Device Identification; Observation - CARLO GAVAZZI PD30ETB BP IO Serie Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 129

7.2. IO-Link Device Parameters for PD30ETB IO-Link

7.2.1. Device Identification

Index Dec
Parameter Name
Vendor Name
16 (0x10)
Vendor Text
17 (0x11)
Product Name
18 (0x12)
Product ID
19 (0x13)
Product Text
20 (0x14)
Serial Number
21 (0x15)
Hardware Revision
22 (0x16)
Firmware Revision
23 (0x17)
Application Specific Tag
24 (0x18)
Function Tag
25 (0x19)
Location Tag
26 (0x1A)
Process-DataInput
40 (0x28)

7.2.2. Observation

Index Dec
Parameter Name
Process data configuration
70 (0x46)
Analogue value
1 (0x01)
Switching Output 1
2(0x02)
Switching Output 2
3 (0x03)
Switching Signal Channel 1
4 (0x04)
Switching Signal Channel 2
5 (0x05)
Dust alarm 1
6 (0x06)
Dust alarm 2
7 (0x07)
Temperature alarm
8 (0x08)
Short-circuit
9 (0x09)
Application Function Output 1
12 (0x12)
Access
Default value
(Hex)
RO
Carlo Gavazzi
RO
www.gavazziautomation.com
(Sensor name)
RO
e.g. PD30ETBR20BPA2IO
(EAN code of product)
RO
e.g. 5709870398945
e.g.Photoelectric Sensor,
Background Suppression, Red Light
RO
Emitter, 200 mm, Stainless Steel
Housing, IO-Link
(Unique serial number)
RO
e.g. 20210315C0001
RO
RO
R/W
R/W
R/W
RO
Access
Default value
(Hex)
R/W
R/W
R/W
1 = Switching Output 1 Active
R/W
1 = Switching Output 2 Active
R/W
0 = SSC1 Inactive
R/W
0 = SSC2 Inactive
R/W
0 = DA1 Inactive
R/W
0 = DA2 Inactive
R/W
0 = TA Inactive
R/W
0 = SC Inactive
R/W
0 = AFO1 Inactive
Data range
e.g. V01.00
e.g. V01.00
***
Any string up to 32 characters
***
Any string up to 32 characters
***
Any string up to 32 characters
-
Data range
-
1 = Normal
2 = Object Length
3 = Object Speed
4 = Counter Value
0 = Switching Output 1 Inactive
1 = Switching Output 1 Active
0 = Switching Output 2 Inactive
1 = Switching Output 2 Active
0 = SSC1 Inactive
1 = SSC1 Active
0 = SSC2 Inactive
1 = SSC2 Active
0 = DA1 Inactive
1 = DA1 Active
0 = DA2 Inactive
1 = DA2 Active
0 = TA Inactive
0 = SC Inactive
0 = AFO1 Inactive
1 = AFO1 Active
Rev.00 - 06 .2021 | MAN PD30ETB IO-Link EN | © 2021 | CARLO GAVAZZI Industri
Data Type
-
StringT
-
StringT
-
StringT
-
StringT
-
StringT
-
StringT
-
StringT
-
StringT
StringT
StringT
StringT
-
IntegerT
Data Type
-
-
0 = Inactive
1 = Normal
RecordT
RecordT
RecordT
RecordT
RecordT
RecordT
RecordT
RecordT
1 = TA Active
RecordT
1 = SC Active
RecordT
Length
20 Byte
34 Byte
20 Byte
13 Byte
30 Byte
13 Byte
6 Byte
6 Byte
max 32 Byte
max 32 Byte
max 32 Byte
32 bit
Length
-
16 bit
16 bit
16 bit
16 bit
16 bit
16 bit
16 bit
16 bit
16 bit
16 bit
37

Publicidad

Tabla de contenido
loading

Tabla de contenido