7.2.5. Sensor specific adjustable parameters

Parameter Name
Selection of local/remote
adjustment
SP1 Trimmer value
Sensor Filter pre-set
Temperature Alarm Threshold
High Threshold
Low Threshold
Safe limits
SSC 1 - Safe limit
SSC 2 - Safe limit
Filter scaler
LED indication
CutOff distance
Hysteresis Mode
SSC1 Auto hysteresis value
AutoHysteresisValueSP1
AutoHysteresisValueSP2
Minimum Excess Gain Level
Minimum Excess Gain Level
Dust response time
Dust reset time
Mutual interference protection
40
Rev.00 - 06.2021 | MAN PD30ETB IO-Link EN | © 2021 | CARLO GAVAZZI Industr6
Index Dec
Access
(Hex)
68 (0x44)
R/W
210 mm for PD30ETBx20...
69 (0x45)
RO
260 mm for PD30ETBS25...
360 mm for PD30ETBR35...
71 (0x47)
R/W
72 (0x48)
-
1 (0x01)
R/W
2 (0x02)
R/W
73 (0x49)
-
1 (0x01)
R/W
2 (0x02)
R/W
5% for PD30ETBS25...
4% for PD30ETBR35...
77 (0x4D)
R/W
78 (0x4E)
R/W
1 = LED indication Active
250 mm for PD30ETBx20...
79 (0x4F)
R/W
300 mm for PD30ETBS25...
400 mm for PD30ETBR35...
80 (0x50)
R/W
0 = Hysteresis set manually
81 (0x51)
-
14 mm for PD30ETBx20...
1 (0x01)
RO
17 mm for PD30ETBS25...
24 mm for PD30ETBR35...
14 mm for PD30ETBx20...
2 (0x02)
RO
17 mm for PD30ETBS25...
24 mm for PD30ETBR35...
82 (0x52)
-
1 (0x01)
R/W
2 (0x02)
R/W
3 (0x03)
R/W
84 (0x54)
R/W
Default value
1 = Trimmer input
23 ... 210 mm for PD30ETBx20...
23 ... 260 mm for PD30ETBS25...
23 ... 360 mm for PD30ETBR35...
0 = Default precision
2 = Customized (filter scaler)
-
70°C
-20°C
-
5% for PD30ETBx20...
5% for PD30ETBS25...
4% for PD30ETBR35...
5% for PD30ETBx20...
1
0 = LED indication Inactive
1 = LED indication Active
20 ... 250 mm for PD30ETBx20...
20 ... 300 mm for PD30ETBS25...
20 ... 400 mm for PD30ETBR35...
0 = Hysteresis set manually
1 = Hysteresis set automatically
-
20 ... 225 mm for PD30ETBx20...
20 ... 275 mm for PD30ETBS25...
20 ... 375 mm for PD30ETBR35...
20 ... 225 mm for PD30ETBx20...
20 ... 275 mm for PD30ETBS25...
20 ... 375 mm for PD30ETBR35...
-
1
2
2
0 = Off
Data range
Data Type
0 = IO-Link adjust
1 = Trimmer input
UIntegerT
2 = Teach-by-wire
UIntegerT
0 = Default precision
1 = High precision
UIntegerT
-
-30 ... 70°C
IntegerT
-30 ... 70°C
IntegerT
-
1 ... 100%
IntegerT
1 ... 100%
IntegerT
1 ... 255
UIntegerT
UIntegerT
2 = Find my sensor
UIntegerT
UIntegerT
-
UIntegerT
UIntegerT
-
1.00 ... 1 000.00
UIntegerT
1 ... 255
UIntegerT
1 ... 255
UIntegerT
0 = Off
1 = 1sensor mode
2 = 2sensor - sensor1
3 = 2sensor - sensor2
Uinteger
4 = 3sensor - sensor1
5 = 3sensor - sensor2
6 = 3sensor - sensor3
Length
8 bit
16 bit
8 bit
-
-
16 bit
16 bit
-
-
8 bit
8 bit
8 bit
8 bit
16 bit
8 bit
-
-
16 bit
16 bit
-
-
32 bit
8 bit
8 bit
8 bit