Powder Coated & Stainless Steel Restroom Partitions, Floor-Braced — Series 500
9
Urinal Screens with Stirrup Brackets (Standard)
Before installing the urinal screen components,
determine the correct location for your application.
Draw a plumb line on the wall to represent the urinal screen
centerline . Measure from the highest point in the room and
A
place a mark on the urinal screen centerline at dimensions
"A" and "B" for the respective urinal screen height (see table
below) .
Position and center brackets at each mark and urinal screen
B
centerline . Using the bracket as a template, mark the hole
locations on the wall . Remove the bracket and drill a Ø5/16"
hole (minimum 2" [51mm] deep) at each hole location .
C
Insert plastic anchors in all holes and secure bracket to the
wall with the #14 x 2" screws provided .
Place the urinal screen at dimension "C" for the respective
D
urinal screen height (see table on right) and insert it into the
wall brackets until a 1" (25mm) gap between the wall and
urinal screen is established .
Using the bracket as a template, drill Ø3/16" holes through
E
the urinal screen at each bracket hole . Secure the urinal
screen to the brackets with the #14 x 5/8" screws provided .