Bradley 500 Serie Manual De Instalación página 8

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Powder Coated & Stainless Steel Restroom Partitions, Floor-Braced — Series 500
3a
Continuous Brackets to Pilaster (Optional)
Refer to the submittal drawing to locate the split
dimension and layout location of each marked pilaster.
Brackets are used as templates but since the hole patterns
may be different, the brackets may not be interchangeable.
Continuous stainless steel bracket shown.
Dim . "A"
Dim . "B"
Stainless
1/2"
57-1/2"
Steel
(13mm)
(1461mm)
Bracket
Aluminum
1/4"
57-3/4"
Bracket
(6mm)
(1467mm)
3b
Alcove Brackets to Pilaster (Optional)
Layouts that use continuous aluminum brackets for pilaster and panel connections will use stirrup brackets
for alcove connections. Continuous stainless steel brackets use continuous alcove brackets.
Refer to the submittal drawing for the layout location of each alcove pilaster
Measure down from the top of
A
the pilaster and place a mark at
dimensions shown for the respective
bracket situation .
Stirrup: Postiion the center of each
B
bracket at the marks made in Step A .
Continuous: Center the bracket
between each mark made in Step A .
Using the bracket as a template, mark
C
the hole locations on the pilaster .
Remove the bracket and drill Ø3/16"
holes throught the pilaster at each
location .
Secure the bracket(s) to the
D
pilaster using the #14 x 5/8" screws
(stainless on continuous) provided .
8
C L
"A"
"B"
Stirrup
6"
(152mm)
52"
(1321mm)
3/22/2018
Measure down from the top of the pilaster and place a mark
A
on the pilaster split centerline at dimensions "A" and "B" for
the respective bracket (see table on left) .
Pilaster shown is for reference only. Actual
pilaster varies depending on application.
Place the continuous bracket between each established
level line . Center the bracket opening on the pilaster split
B
centerline . Using the bracket as a template, mark the hole
locations on the pilaster . Remove the bracket and drill a
Ø3/16" pilot hole (through inside face of pilaster only) at
each location .
C
Secure the continuous bracket to the pilasters using the
#14 x 5/8" stainless screws provided .
57-1/2"
(1461mm)
Bradley • HDWT-INSTR-010 Rev F; ECN 17-14-007
Installation
Continuous
1/2"
(13mm)

Publicidad

Tabla de contenido
loading

Tabla de contenido