• DANGER: The lamp inside the unit emits ultraviolet light that can cause permanent damage to skin
and eyes. Never look at the lamps when unit is operating.
• Never attempt to operate your Vitapur® UV system unless it has first been properly grounded,
to avoid creating an electric shock hazard.
• To prevent an electric shock, do not plug the Vitapur® UV system into any socket that has not
been equipped with a Ground Fault Circuit Interrupter (GFCI).
• Always unplug the power cord before attempting to install, clean or perform other routine
maintenance on the unit.
• Always stop the inlet water flow before performing any maintenance on the unit.
• Do not attempt to service this unit unless you are an accredited service technician, as personal
injury could result and/or system operation could be detrimentally affected.
• Never operate this unit in an oxygen-rich environment, or within 6 feet (2 meters) of any oxygen
source.
• If temperatures should fall below freezing (0°C / 32°F), drain all water from the unit, drain and
disconnect all plumbing lines, and cap the inlet and outlet ports.
p
o
roduct
vervIew
The Vitapur
Ultraviolet (UV) Water Treatment System has been engineered to rigid standards, and
®
has been quality inspected at the factory prior to packaging. Please review this manual in its entirety
for a detailed system explanation, and ensure that the following components accompany this
system: To ensure system performance, all replacement components should be purchased directly
from an authorized dealer or directly from Greenway Water Technologies (www.greenwaywt.com).
The use of components purchased from other sources will void the warranty, and will potentially
cause the system to function in a lesser capacity than intended.
Ultraviolet (UV) Water Treatment System
Installation Instructions & Owner's Manual
System tested and certified by NSF
International against NSF/ANSI Standard
55 and CSA B483.1 for disinfection performance
NSF-55 CLASS A: VUV-S375MA, VUV-S645MA, VUV-S940MA,
VUV-H375MA, VUV-H645MA, VUV-H940MA
NSF-55 CLASS B
:
VUV-S375B, VUV-S375MB, VUV-S645B, VUV-S645MB,
VUV-S940B, VUV-S940MB, VUV-H375B, VUV-H375MB, VUV-H645B,
VUV-H645MB, VUV-H940B, VUV-H940MB
CAUTION: Before using UV System, read this manual and follow all safety rules and operating instructions.
x2
Lamp Failure
!
(red)
Power
(green)
:
uv
SyStemS wIth monItor port optIon
Owners Manual
Lamp Failure
!
(red)
Power Cord
Power
(green)
VuCap
UV Cylinder
Mounting
Clamps and
screws
Retaining Nut
Quartz Sleeve
Sealing O-Ring
Hardware Kit
Stainless Steel UV Reaction Chamber
(2 screws, 2 anchors)
Lamp Failure
!
(red)
Power
Electronic Ballast
(green)
Lamp Failure
!
(red)
(Includes lamp connector)
Power
(green)
UV Lamp
Quartz Sleeve
f
1
Igure
2
Flow Restrictor
Ring
Glass Insert
O-Ring