Troubleshooting - vitapur VUV-S375MA Instrucciones De Instalación Y Manual Del Propietario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

t
roubleShootIng
PROBLEM
Warm water output
Unit leaking water
No power to UV lamp
when system is plugged
in
System has power but UV
lamp is not coming on
(visible / audible alarm
activated)
System is vibrating
Excessive heat
generated
*Water Hammer: Sudden closure of a control valve or stopping of a pump produces excessive pressure surges in a
pipeline. These pressure surges can cause significant damage to equipment and/or appliances directly attached to
the water line. Water hammer is usually noted due to the characteristic banging sounds when valves on the line are
suddenly closed. Water hammer conditions must be immediately remedied, and damage to systems as a result of this
condition are not covered under warranty.
If you experience trouble with your system other than the symptoms described above, please visit:
Greeway Water Techologies - Guelph, ON, Canada N1K 1B2 - Niles, IL, USA 60714 1-888-592-8370
www.ghpgroupinc.com
g
:
uIde
POSSIBLE CAUSE
Water sitting in UV reaction chamber
and heating up due to infrequent use
Misaligned or cross-threaded
connections on inlet / outlet ports
Excessive water pressure
Water hammer* causing pressure spikes
GFCI wall socket is tripped
Lamp not installed correctly
Lamp failure
Not mounted securely
Water hammer* causing vibrations
Not being allowed sufficient space for
cooling
Operated in an excessive ambient
temperature
Water temperature is too high
System tested and certified by NSF
International against NSF/ANSI Standard
55 and CSA B483.1 for disinfection performance
Run tap for a short period of time
Reinstall to ensure a solid connection
with ports
Install pressure regulator ahead of
system
Install a "Water Hammer" arrestor in
system
Reset, following manufacturer's
instructions provided with the outlet
Check socket with other appliances
Ensure lamp is installed correctly with
electrical fitting (must be snug)
Replace UV lamp
Secure fasteners
Install a "Water Hammer" arrestor in system
Clear space for cooling (min. 6-12" / 15-
30 cm clearance around unit)
Unplug unit until temperature is within
ambient operating conditions
Ensure treatment is on cold water side
only (prior to heating of water)
11
SUGGESTED SOLUTION