The electronic control unit SA.03 Head can be used to control 2 motors with a power not exceeding
350+350W.
a) The wire connections and the operating logic should be in compliance with regulations in force.
b) The cables featuring different voltage should be physically detached, or adequately insulated by an additional
insulation of at least 1 mm.
c) The cables should be further fastened in proximity to the terminals.
d) Check all connections before powering the unit.
e) Check that settings of the Dip-switches are the required ones.
f)
The N.C. inputs which are not in use should be short-circuited.
Terminal No.
1-2
3-4
5-6-7
8-9-10
11-12
13-14
11-15
16-17
18-19
20
21
22
23
24
25-26-27
28-29-30
J3
To check connections:
1) Cut-off power supply.
2) Manually release the wings, move them to approx. half-stroke and lock them again.
3) Reset power supply.
4) Send a step-by-step control signal by pressing the button or the remote control key.
5) The wings should start an opening movement. If this is not the case, invert the movement wires of the motor.
(8/10 for motor M1, and 5/7 for motor M2).
6) Adjust Time, Operating Logic and Motor Power.
WARNING! This adjustment affects the safety of the automatic system.
Check that the thrust applied onto the wing complies with regulations in force.
A Faston (T1) connector is provided on the power supply transformer which allows the power adjustment of the
motors on 4 different levels. By moving the Faston (T1) to 120, power is at minimum, by moving it to 230, power
is at maximum.
Position 230 can be used only with motors complete with adjustable mechanical clutch.
In any case, check compliance with regulations in force.
6
SA.03 Head Control Unit
INPUT/OUTPUT FUNCTIONS
Function
Description
Power supply
Input, 230Vac 50Hz (1-Phase/2-Neutral)
Flashing light
Output, flashing light connection, 230Vac 40W max.
Motor 2
Connection to motor 2 : (5-move/6-Com/7-move)
Motor 1
Connection to motor 1 : (8-move/9-Com/10-move) – delayed in closing
phase. If only one motor is used, connect Motor 1 output and adjust
TRAC to the minimum value.
24 Vac
Output, accessories power supply 24Vac/1A max.
Electric lock
Electric lock connection, 12Vac/0,5A max.
SCA
Open gate indicator light connection, 24 Vac/3W max.
RX 2ch.
Output, second radio channel. N.O. contact, voltage free.
It is enabled with both fixed receiver and expandable two-channel re-
ceiver
Aerial
Aerial connection, radio receiver card and incorporated radio module
(18-screen/19-signal).
Pedestrian
Input, N.O. pedestrian push-button
Activation is carried out on motor M1 (8-9-10)
Step-by-Step
Input, N.O. step-by-step push-button
STOP
Input, N.C. STOP push-button
PHOT
Input, safety devices connection, N.C. terminal (e.g. photocells)
+V
Common to all control inputs.
0-24-12
Connection to transformer secondary winding
L1-T1-N1
Connection to transformer primary winding
Radio receiver
Connector for two-channel radio receiver (optional)

GENERAL WARNINGS

To adjust the motor power

Publicidad

Tabla de contenido
loading