The control unit can be used to control 230Vac motors with power not exceeding 350W.
a) The electrical installation and operating logic must comply with statutory regulations.
b) Cables of different voltages must be physically separated or otherwise adequately screened with
secondary insulation of at least 1 mm.
c) Cables must be secured by additional clamps next to their terminals.
d) Control all wiring connections are correct before powering.
e) Check the Dip-Switch settings are correct.
f) Unused N.C. inputs must be jumpered.
Terminals Function
1-2-3
Power supply
4-5
Antenna
6
COM
7
Step-by-Step
8
PED
9
STOP
10
PHOT2
11
PHOT1
12
COM
13-14
COSTA
15-16
24 Vac
17-18
SCA/II°ch
19
SWO
20
SWC
21
COM
22-23-24
Secondary
25-26-27
Motor, 230V
25-28
Capacitor
29-30
Flasher
31-32
Primary
Control units CP.MS4

GENERAL RULES

INPUT/OUTPUT FUNCTIONS
Description
Input, 230VCA 50Hz (1-Neutral/2-Phase/3-GND)
Connection, radio receiver board antenna (4-signal/5-screen).
Common to control inputs.
Input, step-by-step button (N.O contact), operation presettable by Dip-
Switch 4.
Input, PEDESTRIAL push-button (N.O. contact), opens for about 7 sec-
onds.
Input, STOP push-button (N.C. contact)
Input, connection to safety devices, N.C. contact (e.g. photocells)
This input is activated only during closure.
When the contact is open, the motor stops and immediately reverses its
movement (the gate opens).
Input, connection of safety devices, N.C. contact.
(e.g. photocells) Input activated in the opening and closing phases.
During opening: when the contact is open, the motor stops and when the
photocell is no longer darkened, the motor re-starts in the opening phase.
During closure: when the contact is open, the motor stops and when the
photocell is no longer darkened, the motor movement is reversed (the gate
opens).
Common to photocell inputs.
Input, sensitive safety edge
Resistive edge: Jumper "DAS" closed
Mechanical safety edge: Jumper "DAS" open
When the safety edge is activated, the gate movement is stopped and the
movement reversed for about 3 sec.
If the safety edge is not in use: "DAS" Jumper open and jumper between
terminals 13-14.
Output, 24VCA/0.5A max power supply of accessories
Output, N.O. contact. It can be preset as open gate indicator light, 2
channel through DIP 1.
Input, OPENING limit switch (N.C. contact).
Input, CLOSING limit switch (N.C. contact).
Common, limit switch
Connection, winding of secondary transformer, 24V
(22:12V/23:0V/24:12V)
Connection to motor (25:OPEN/26:COM/27:CLOSE)
Connection to capacitor
Connection of flasher, 230VCA 40Wmax.
Connection, winding of primary transformer (31:L/32:N)
radio
nd
7