General Warnings; Programming - Beninca brain Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 24
The BRAIN electronic control unit may be used for the control of 1 or 2 motors with power not higher than 500W+500W.
a) The electrical installation and the operating logic must comply with the regulations in force.
b) The leads fed with different voltages must be physically separate, or they must be suitably insulated with additional insulation of
at least 1 mm.
c) The leads must be secured with an additional fixture near the terminals.
d) Check all the connections again before switching on the power.
e) The unused N.C. inputs must be bridged.
N° Terminals
Function
1-2-3
Power supply
4-5-6
Motor 1
7-8-9
Motor 2
10-11
Blinking light
12-13
TLS
14-15
24 Vac
16-17
Lock 12Vac
18-19
SCA
20-21
EDGE
22
SWO-M1
23
SWC-M1
24
SWO-M2
25
SWC-M2
26-27
COM
28
Step-by-Step
29
PED
30
OPEN
31
CLOSE
32
PHOT
33
PHOT CLOSE
34
STOP
35-36
Antenna
37-38
RX 2ch.
J3
Radio
The EDGE must be connected exclusively to the special inputs 20/21. Two types of EDGE may be used:
If an edge with resistance 8K2 is used, close the Jumper "DAS".
If a mechanical edge with N.C. contact is used, open the Jumper "DAS".
If the edge is not used, bridge the terminals 20-21 and open the Jumper "DAS".
The programming of the various functions of the control unit is carried out using the LCD display on the control unit and setting
the desired values in the programming menus described below.
The parameters menu allows you to assign a numerical value to a function, in the same way as a regulating trimmer.
The logic menu allows you to activate or deactivate a function, in the same way as setting a dip-switch.
Other special functions follow the parameters and logic menus and may vary depending on the type of control unit or the software
release.
BRAIN CONTROL UNIT

GENERAL WARNINGS

INPUT/OUTPUT FUNCTIONS
BRAIN CONTROL UNIT
Description
Input 230Vac 50Hz (1-GND/2-Phase/3-Neutral)
Connection of motor 1: (4-start/5-Com/6-start)
Connection of motor 2: (7-start/8-Com/9-start)
Connection of blinking light 230Vac 40W max.
N.O. clean contact for courtesy light, timer, etc.
The activation time is regulated by the parameter TLS
Accessories power supply output 24Vac/0.5A max.
Accessories power supply output 12Vac/10W for electric lock (16:0V, 17:+12V)
N.O. clean contact for gate open warning light.
Input, sensitive edge contact
Resistive edge: "DAS" Jumper closed
Mechanical edge: "DAS" Jumper open
When the edge is activated, the gate movement is stopped and reversed for about 3s.
OPEN limit switch input motor 1 (N.C contact.)
CLOSE limit switch input motor 1 (N.C. contact)
OPEN limit switch input motor 2 (N.C. contact)
CLOSE limit switch input motor 2 (N.C. contact)
Common for limit switch and all the control inputs.
Step-by-Step button input (N.O. contact)
Pedestrian button input (N.O. contact)
OPEN button input (N.O. contact), configurable as Clock contact
CLOSE button input (N.O. contact)
Active photocell input on opening and closing
Active photocell input only on closing
STOP button input (N.C. contact)
Antenna connection for plug-in radio receiver board (35-screen/36-signal).
Second radio channel output of the plug-in receiver.
Voltage-free N.O. contact.
Plug-in connector for radio receiver.
NOTES

PROGRAMMING

9

Publicidad

Tabla de contenido
loading

Tabla de contenido