Cord Sets And Receptacles - Briggs & Stratton POWERBOSS Manual Del Propietário

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Cord Sets and Receptacles

Use only high quality, well-insulated, grounded extension
cords with the generator's receptacles. Inspect extension
cords before each use.
Check the ratings of all extension cords before you use
them. Extension cord sets used should be rated for AC loads
15 Amps or greater. Check operator's manuals of devices to
be powered for the manufacturer's recommendations.
Keep extension cords as short as possible to minimize
voltage drop.
WARNING Damaged or overloaded electrical cords
could overheat, arc, and burn resulting in death,
serious injury, and/or property damage.
• ONLY use cords rated for your loads.
• Follow all safeties on electrical cords.
• Inspect cord sets before each use.
10
120 Volt AC, 20 Amp, Duplex Receptacle
The duplex receptacle is protected against overload by a
push to reset circuit breaker.
Use receptacle to operate 120 Volt AC, single–phase, 60 Hz
electrical loads requiring up to 1,700 watts (1.7 kW) at
14.1 Amps of current. Use cord sets that are rated for
125 Volt AC loads at 15 Amps (or greater).
NOTICE Receptacles may be marked with rating value
greater than generator output capacity.
• NEVER attempt to power a device requiring more amperage than
generator or receptacle can supply.
• DO NOT overload the generator. See Don't Overload Generator.
www.powerboss-equipment.com

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido