The second radio channel is enabled or disabled on terminal AUX.
On: AUX output, preset as second radio channel.
2CH
SERL, TST1 and TST2 logics should be preset on OFF.
Off: AUX output can be preset as SCA, or by SERL, TST1 and TST2 logics.
The service light function is enabled or disabled on AUX output.
On: At each operation the contact is closed for the time preset with TLS
SERL
parameter. TST1 and TST2 logics should be preset on OFF.
For the light control, use an auxiliary relay.
Off: AUX output can be preset as SCA, or by 2CH, TST1 and TST2 logics.
Check of photocells on PHOT O input is enabled or disabled.
TST1
On: check is enabled. If check is not successful, no operation is enabled.
Off: AUX output can be preset as SCA, or by 2CH, SERL and TST2 logics.
Check of photocells on PHOT C input is enabled or disabled.
TST2
On: check is enabled. If check is not successful, no operation is enabled.
Off: AUX output can be preset as SCA, or by 2CH, SERL and TST1 logics.
The operating mode of the PHOT C input is selected.
On: PHOT C input is activated in both opening and closing phases.
In the opening phase: the contact opening causes the motor stop. When the
photocell is released, the motor restarts in the opening phase.
PHTC
In closing phase: the contact opening causes the motor stop. When the photocell
is released, the motor inverts the movement direction (open).
Off: The PHOT C input is activated in the closing phase only.
In the closing phase: the contact opening causes the motor stop and the
immediate reversion of the operation direction (open).
PP input as OPEN and PED input as CLOSED are enabled or disabled.
OPCL
On: PP input is enabled as OPEN and PED input is enabled as CLOSED.
Off: PP and PED inputs are enabled with their function.
Enables or disables starting torque function.
On: Starting torque enabled. At the start of each manoeuvre for 2s the motor
SPN
operates at maximum torque.
Off: Starting is performed at reduced speed for 2s and then movement is
restored to normal speed.
MENU
By selecting this function, the receiver awaits (Push) for a transmitter code to be assigned to the step-
by-step function.
PP
Press the transmitter key to be assigned to this function.
If the code is valid, it is stored in memory and OK appears.
If the code is not valid, the wording Err is displayed.
By selecting this function, the receiver awaits (Push) for a transmitter code to be assigned to the second
radio channel.
2Ch
Press the transmitter key to be assigned to this function.
If the code is valid, it is stored in memory and OK appears.
If the code is not valid, the wording Err is displayed.
By selecting this function, the receiver awaits (Push) for a transmitter code to be erased from memory.
CLR
If the code is valid, it is erase and OK appears.
If the code is not valid or is not in memory, the wording Err is displayed.
RTR
Completely erase the receiver memory. Confirmation of operation is required.