3. Cement 1-1/4in. PVC MPT×S Male Adapter into 1-
1/4 in. PVC rigid pipe. Install 1-1/4in.PVC TEE
FPT×FPT×FPT to adapter. One end of horizontal
port installs another 1-1/4in. PVC MPT×S Male
Adapter and 1-1/4 in. PVC rigid pipe. Add sections
of pipes to reach the 1-1/4in. PVC Slip ×Slip Union
(optional). (Fig. 3)
2. WELL TO PUMP CONNECTION
1.
Thread 1-1/4in. PVC MPT×S Male Adapter into
pump. Cement a short horizontal 1-1/4 in. PVC rigid
Pipe into adapter. (Fig .1)
3.
Completed installation is shown Fig. 3a.3b.3c.
For Cased well
6
2.
Cement a 1-1/4in. PVC Slip× Slip Union into a short
horizontal 1-1/4 in. PVC rigid Pipe. Slopes all inlet
piping slightly upward from well to the pump to
prevent trapping air. (Fig.2)
For Well Point
For Professional Technical Support call 1-844-242-2475
For Surface water