Error Diagnosis (Fig.8); Recycling The Product - ASBER T-OEM-350 Instrucciones De Instalación, Uso Y Mantenimiento

Ocultar thumbs Ver también para T-OEM-350:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 7
EN
Machine stops during
operation.
Machine stops and fills
with water when it is
washing.
The machine does not
start with the wash cycle.
Machine does not drain
completely.
NOTE: If a fault occurs and is not listed in the above table, please call the
technical service. The manufacturer reserves the right to modify the
technical characteristics with prior warning.

6.1 Error diagnosis (Fig.8)

ERROR
DESCRIPTION
E1
OPEN DOOR
E2
TANK FILL
E3
TANK DRAINAGE
E4
BOILER HEATING
E5
TANK HEATING

7. RECYCLING THE PRODUCT

The European Directive 2012/19/EU relating to Waste Electrical and Electronic Equipment
(WEEE) states that household appliances should not be disposed of using the normal solid
urban waste cycle. Exhausted appliances should be collected separately in order to optimise
the cost of re-using and recycling the materials inside the machine, while preventing
potential damage to the atmosphere and to public health. The crossed-out dustbin is marked
on all products to remind the owner of their obligations regarding separated waste collection.
For more information relating to the correct disposal of household appliances, owners
should contact their local authorities or appliance dealer.
Electrical installation
overloaded.
Machine protection has
tripped.
Pressure switch pipe blocked.
Pressure switch faulty.
Overflow incorrectly mounted.
Door is not closed properly.
Door micro switch faulty.
Machine not levelled correctly.
Pressure switch faulty.
The ON/OFF LED lights up for 0.5 seconds and then remains unlit for 2
seconds before lighting up again. This continues as long as the door is open
and the selected cycle is unfinished.
The ON/OFF LED light up twice for 0.5 seconds each time and then remains
unlit for 2 seconds, then lighting up again twice. This continues while the
water in the tank does not reach the correct level in the specified time.
The ON/OFF LED lights up three times for 0.5 seconds each time and then
remains unlit for 2 seconds, then lighting up again three times. This
continues while the drainage pump does not drain the water in the tank to
the correct level in the specified time.
The ON/OFF LED lights up four times for 0.5 seconds each time and then
remains unlit for 2 seconds, then lighting up again four times. This continues
while the water in the boiler does not reach the correct temperature in the
specified time.
The ON/OFF LED lights up five times for 0.5 seconds each time and then
remains unlit for 2 seconds, then lighting up again five times. This continues
while the water in the tank does not reach the correct temperature in the
specified time.
Call technical service to modify electrical installation.
Reset safety device and if it trips again, call technical
Empty the tub and clean thoroughly.
Call the technical service to replace it.
Mount overflow correctly.
Close the door correctly and if it is seen to re-open
alone, call the technical services to adjust the
Call the technical service to replace it.
Level the machine In the event of doubt, please
contact your technical service.
Call the technical service to replace the pressure
CONSEQUENCE
51
service.
tensioneers.
switch.