Gasoline expands or contracts with ambient
temperatures. Never fill the gasoline tank to full
capacity, as gasoline needs room to expand if
temperatures rise.
Liquid Petroleum Gas (LPG/Propane):
This generator is dual fuel and capable of running
with both gasoline and Liquid Petroleum Gas
(LPG/Propane).
DANGER
•
Liquid Petroleum Gas (LPG) is highly flammable
and explosive. Fire or explosion can cause severe
burns or death.
•
Do not use or store LPG cylinder in a building,
garage or enclosed area.
•
Do not check for leaks with a lighted match or
flame.
•
The LPG cylinder valve should be fully closed
when the generator is not in use or is running
with gasoline.
•
If you smell gas: close off the gas supply. Make
sure there is no leak before using the generator.
English
•
Device used for handling LPG must be installed
and used in strict conformance with NFPA 58
(Liquefied Petroleum Gas Code) and NFPA 54
(National Fuel Gas) and all other codes,
regulations and manufacturer recommendations.
•
Never use a gas container, LPG connector hose,
LPG cylinder or any other fuel item that is
damaged or appears damaged.
•
The LPG cylinder valve should be fully closed
when the generator is not in use or is running
with gasoline.
•
The regulator/hose assembly and cylinder valve
must be inspected before each use for leaks or
Page 06
sign of damages.
•
If you smell gas: close off the gas supply. Spray a
soapy water solution to check all connections for
leaks before attempting to use generator.
Contact a qualified technician to inspect and
repair the LPG system if a leak found before using
the generator.
CAUTION
•
LPG under pressure is highly flammable and can
cause a fire or explosion if ignited.
Customer Service: 1-844-FIRMAN1