"START" position and repeat the "PULL-TO-
PRIME" step.
11. Allow generator to run at no load for few
minutes upon each initial start-up to permit engine
and generator to stablize.
MUST
REMINDER:
INDICATOR LIGHT TO BE ABLE TO START THE
GENERATOR. THE GENERATOR CANNOT BE
STARTED DURING BATTERY POWER SAVING
MODE UNLESS THE FUEL SELECTOR SWITCH IS
TURNED TO THE "OFF" POSITION AND THEN
TURNED BACK TO THE "LPG" POSITION.
See Indicator light-Battery power Saving Mode
section for more information.
WARNING
When starting engine, pull cord slowly until
resistance is felt and then pull rapidly to avoid
kickback.
Keep choke lever in "START" position for only 1 pull
of the recoil starter. After first pull, move choke
lever to the "RUN" position for up to the next 3 pulls
of the recoil starter. Too much choke leads to
sparkplug fouling/engine flooding due to the lack
of incoming air. This will cause the engine not to
start.
Starting the Generator (Electric Start-
Gasoline)
1. Before starting the generator, check for loose
4. Turn the fuel selector switch to "GAS" position.
English
HAVE
SOLID
RED
NOTE: When the fuel selector switch is turned to
the "GAS" position, the indicator light will become
RED up to 4 minutes(before goes off). Starting the
engine successfully during these 4 minutes will
turn the indicator light GREEN. 5. Disconnect all
electrical loads from the generator. Never start or
stop the generator with electrical devices plugged
in or turned on.
Customer Service: 1-844-FIRMAN1Page 13