Descargar Imprimir esta página

Manual Regeneration; Power Loss - vitapur Pro Soft VWS296GR Manual De Uso

Publicidad

Idiomas disponibles

Idiomas disponibles

The time settings for Brine & Rinse and Brine Refill are in the tables below at low, medium and high salt setting.
Time Settings For Brine Refill And Brine & Rinse At Low Salt Setting (table D):
Salt Setting
Low salt setting
Medium Salt Setting
High Salt Setting
If changing the salt setting to low or high salt setting, the first step is to change the capacity (Amount of Soft Water Available) by
following the procedure in Section 4 "Set Capacity". Use the tables A or C on pg 11.
To change the salt setting from the default medium salt setting to low or high salt setting the times for Brine & Rinse and Brine
Refill have to be changed. Follow the steps below.
Step 1.
If starting at In-Service menu press Menu/Return key
scroll down to "Advance Settings" using the arrow keys.
Step 2.
Press the Menu/Confirm Key
Step 3.
Scroll down to "Brine and Rinse" in the sub menu set up using the down arrow key
Step 4.
Press the Menu/Confirm Key
in Table D to adjust the times if you prefer low salt setting or high salt setting.
Step 5.
Use the down or up arrow keys
Step 6.
Press the Menu/Confirm Key
times for your preference of low or high salt setting. Use the down or up arrow keys
minute setting.
Step 7.
Press the Menu/Confirm Key
Step 8.
Scroll down to "Brine Refill".
Step 9.
Press the Menu/Confirm Key
for your preference of low or high salt setting.
Step 10.
Use the down or up arrow keys
Step 11.
Press the Menu/Confirm Key
and up arrow keys
Step 12.
Press the Menu/Confirm Key
Step 13.
Press Manual/Return Key twice
going to be changed.
Calendar Day Override:
6.
The calendar day override has been set to 14 days. This means if the water softener water capacity is not used up in 14 days it will
regenerate automatically to help prevent resin fouling.

Manual Regeneration:

7.
1.
Sometimes there is a need to regenerate the system sooner than when the system call for it, usually referred to as manual
regeneration. There may be a period of heavy water usage because of guests or a heavy laundry day. To initiate a manual
regeneration immediately, press the Manual/Return key
Backwash • Brine Draw & Slow Rinse • Fast Rinse • Fill Brine Tank • Back to In Service
Note: Regeneration cycle will take approximately 54 minutes to complete.
2.
When the regeneration cycles are completed the valve will return to the in-service mode.
3.
The only way to cancel a manual regeneration is to cycle fast through the steps by pressing the
Manual/Return Key

Power Loss:

8.
If the power outage exceeds 3 days (72 hours) the clock will need to be reset. When the power is turned on the clock figure
will flicker continuously. This reminds owner to reset the time. All other parameters will not need to be reset.
9.
Hard Water Notice:
During softener regeneration cycle, only hard water will be available in the facility.
Error Message:
10.
If the errors E1, E2, E3 or E4 show on the display screen contact the dealer for assistance.
Brine & Rinse (time - min:sec)
37:00
50:00
54:30
to enter the "Advance Settings" sub menu.
and the minutes in the "Brine and Rinse" will start flashing. Use the appropriate values
to scroll to the correct minutes.
and the seconds will start flashing. Use the appropriate values in Table D to adjust the
and menu will return to the main menu "Brine and Rinse".
and the minutes in the "Brine Refill" will start flashing. Use Table D to select the time
to scroll to the correct minutes.
and the seconds will start flashing. Use table D to select the seconds. Use the down
to adjust to the correct seconds setting.
and menu will return to set-up menu "Brine Refill".
to proceed back to the In Service Display screen if no other parameters are
repeatedly after every cycle until the valve returns to service mode.
Brine Refill (time - min:sec)
1:30
2:00
2:30
to switch to the main menu. If continuing in the main menu
. The control valve will cycle through the following regeneration cycles:
12
.