voestalpine Bohler WF 330 ArcDrive Classic Instrucciones De Uso página 37

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 94
Permits striking at reduced speed, therefore softer and
with less spatter.
Minimum 10%, Maximum 100%, Default 50% (syn)
12
Motor slope
Allows you to set a gradual transition between the
sparking wire speed and the welding wire speed.
Minimum off, Maximum 1.0 sec., Default off
15
Burn back
Permits adjustment of the wire burn time, preventing
sticking at the end of welding.
Permits adjustment of the length.
Permits adjustment of the length of the piece of wire
outside the torch.
Minimum -2.00, Maximum +2.00, Default syn
16
Post-gas
Permits setting and adjustment of the gas flow at the
end of welding.
Minimum off, Maximum 10 sec., Default 2 sec.
24
Bilevel (4 Step - crater filler)
Permits adjustment of the secondary wire speed in the
bilevel welding mode.
If the welder now presses and releases the button quickly,
"
" can be used; by pressing and releasing it quickly
again, "
" is used again, and so on.
Parameter setting: Percentage (%).
Minimum 1%, Maximum 500%, Default off
25
Initial increment
Allows regulation of the wire speed value during the
first "crater-filler" welding phase.
Makes it possible to increase the energy supplied to
the part during the phase when the material (still cold)
requires more heat in order to melt evenly.
Minimum 20%, Maximum 200%, Default 120%
26
Crater filler
Allows regulation of the wire speed value during the
weld closing phase.
Makes it possible to reduce the energy supplied to the
part during the phase when the material is already very
hot, thus reducing the risk of unwanted deformations.
Minimum 20%, Maximum 200%, Default 80%
27
Initial increment time
Lets you set the initial increment time. Lets you auto-
mate the "crater filler" function.
Minimum 0.1s, Maximum 99.9s, Default Off
28
Crater filler time
Lets you set the "crater filler" time. Lets you automate
the "crater filler" function.
Minimum 0.1s, Maximum 99.9s, Default Off
29
(Crater filler, MIG Bilevel) slope
Crater filler:
Allows you to set a gradual passage between the initial wire
speed (initial increment) and the welding wire speed.
Allows you to set a gradual passage between the weld-
ing wire speed and the final wire speed (crater filler).
MIG Bilevel:
Allows a smooth step to be obtained between the peak
wire speed and the basic wire speed, having a more or
less soft welding arc.
Parameter set in seconds (s).
Minimum 0.1s, Maximum 10.0s, Default off
30
Spot welding
Allows you to enable the "spot welding" process and
establish the welding time.
Minimum 0.1s, Maximum 25s, Default off
31
Pause point
Allows you to enable the "pause point" process and
establish the pause time between one welding opera-
tion and another.
Minimum 0.1s, Maximum 25s, Default off
32
Secondary voltage (MIG Bilevel)
Allows regulation of the secondary pulsation level volt-
age.
Makes it possible to obtain greater arc stability during
the various pulsation phases.
Minimum -5.0, Maximum +5.0, Default syn
33
Secondary inductance (MIG Bilevel)
Allows regulation of the secondary pulsation level
inductance.
Makes it possible to obtain a quicker or slower arc to
compensate for the welder's movements and for the
natural welding instability.
Low inductance = reactive arc (more spatter).
High inductance = less reactive arc (less spatter).
Minimum -30, Maximum +30, Default syn
202
Inductance
Allows electronic regulation of the series inductance of
the welding circuit.
Makes it possible to obtain a quicker or slower arc to
compensate for the welder's movements and for the
natural welding instability.
Low inductance = reactive arc (more spatter).
High inductance = less reactive arc (less spatter).
Minimum -30, Maximum +30, Default syn
331
Voltage (Synergic MIG/MAG)
Lets you set welding voltage.
500
Allows access to the higher set-up levels:
USER: user
SERV: service
vaBW:vaBW
551
Lock/unlock
Allows the locking of the panel controls and the inser-
tion of a protection code (consult the "Lock/unlock"
section).
601
Regulation step
Allows the regulation of a parameter with a step that can
be personalised by the operator.
Minimum 1, Maximum Imax, Default 1
602
External parameter CH1
Allows the management of external parameter 1 (mini-
mum value).
603
External parameter CH1
Allows the management of external parameter 1 (maxi-
mum value).
606
U/D torch
Allows the management of the external parameter (U/D).
O=off, I=current, 2=program retrieval
653
Wire speed
It allow wire speed regulation (during wire loading
phase).
Minimum 0.5 m/min, Maximum 22 m/min, Default 3
m/min
705
Circuit resistance calibration
Lets you calibrate the system.
Press the encoder knob to access parameter 705.
Place the tip of the wire guide in electrical contact with
the work piece.
Press and hold the torch trigger for at least 1 s.
37

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Bohler wf 330 arcdrive smartBohler wf 330 rapideep steel

Tabla de contenido