3.3.2- SMARTCLORO PLUS PH Series Equipment (SMARTCLPLUSPH15230,
SMARTCLPLUSPH25230, SMARTCLPLUSPH35230)
: Earth connection
L, N: Supply 230v
SW: On / Off Switch
PH: pH pump connecti on
R.AUX: Auxiliary relay
FILTER: Filter connecti on for Stop / Start mode
J4: Terminal block of cell
J8:
1- Acid sensor (PH)
2- Acid sensor (PH)
3- Cover
4- Cover
5- N/C
6- N/C
7- Water sensor (white cable of the cell)
8- Temperature Probe
9- Temperature Probe
10- ORP-
11- ORP+
12- 12v for external FLOW connecti on (7-12)*
* acti vate the FLOW SWITCH operati on in the
confi gurati on menu
3.3.3- Advanced Functions
3.3.3.1- Stop-start control
This mode enables you to keep the equipment on permanently, so that when the fi ltering pump starts up, it
will instruct the chlorinator to start-up. When the pump stops, the screen of the chlorinator will display the
message "stop".
To acti vate this mode, remove jumper "LK2" from the power board, supply the chlorinator directly at 230 V,
and connect the "fi lter" inlets in parallel to the supply of the fi ltering pump.
L
N
K1: PH Relay
K4: Auxiliary relay
LK2: Stop/Start
F1: Fuse
Conexón Control marcha - Paro
L
N
CONEXIÓN
BOMBA PH
3
4
INTERRUPTOR
ENCENDIDO
A la salida de la alimentación
de la bomba de ltración
K1 K4
1 3 5 7 9 11
2 4 6 8 10 12
SW
L N
PH
R.AUX FILTER
J8
CONEXIÓN
CONEXIÓN
RELE AUX
FILTRO
J4
41