WHAT do I do when these problems occurs?
P
ROBLEM
Refrigerant will not feed through the MYSTICOOL
Erratic or "hunting" Expansion Valve
Continued excessive frost buildup on the evaporator coil
Excessive buildup of frost onto the suction line and
compressor service valve
Case or Box temperatures too high
¿Qué debo hacer si algo está dañada en el envío?
Notificar inmediatamente a su oficina local de correo y solicite una inspección. Anotas modelo y
número de serie, a continuación, póngase en contacto con XDX
para asistencia o reemplazo de mercancía dañada.
WHAT should I do if something is damaged in shipment?
Notify your local carrier office immediately and request inspection. Record model and serial number then contact XDX
replacement of damaged merchandise.
¿Qué puedo esperar para reclamos de garantía?
®
XDX
garantiza, a sus compradores directos que todos los productos fabricados por XDX
deberán estar libre de todos los defectos de materiales o mano de obra, bajo condiciones
normales de utilización y servicio por un período de un 1 año desde la fecha de compra.
WHAT can I expect for warranty claims?
XDX
®
warrants, to its direct purchasers that all products manufactured by XDX
service for a period of one (1) year from the date of purchase.
Mientras estas instrucciones de instalación la instalación de la Asamblea MYSTICOOL
condensador remoto o un circuito subenfriador despues de la salida del condensador, si la asamblea de MYSTICOOL
del condensador.
While these installation instructions reference the installation of the MYSTICOOL
remote condenser or a sub-cooling circuit downstream of the condenser outlet, if the MYSTICOOL
.
.
WWW
XDXUSA
COM
®
M
Valve
AX
®
M
14
01
(+1)
847.398.0250
TEL
FAX
P
C
R
OSSIBLE
AUSES OR
EMEDY
Moisture in system
Low refrigerant charge
Bad power head on TX valve
Low side restriction
Undersized TX valve
Improper superheat setting
Oversized TX valve
Poor TX valve bulb location
Improper superheat setting
Low refrigerant charge
Too much liquid sub-cooling
Too few defrost cycles
Unit not cycling properly
Thermostat setting too low
Defective defrost timer
Improper superheat setting
Confirm compressor superheat
Thermostat set too high
Low refrigerant charge
Improper superheat setting
Iced evaporator
®
con el departamento de envío
®
shall be free of all defects, in material or workmanship, under normal use and
®
M
valve adyacente al evaporador de referencia el sistema debe incluir un
AX
valve assembly adjacent to the evaporator the system needs to include either a
AX
®
M
valve assembly is located substantially close to the condenser.
AX
01
(+1)
847.398.1365
WWW
shipping department for assistance or
®
®
valve se encuentra sustancialmente cerca
M
AX
.
.
XDXGLOBAL
®
COM