Operation
1. The shaft seal depends on water for
lubrication. Do not operate the pump unless
it is submerged in water; running it dry may
damage the seal.
2. If the pump overheats, an automatic-reset
thermal protector cuts off the power and stops
the motor before it can be damaged. The motor
will automatically restart when it cools. If the
protector trips repeatedly, unplug the pump,
remove it from the sump, and check it for
Performance
GPH At Total Feet Of Lift
Model
5 ft.
10 ft.
Capacity Gallons/Hour
235817
4,800
4,020
Electrical & Switch Specifications
Model
Motor HP
235817
3/4
Figure 6 – LIFT: Lift is the vertical distance the
pump actually lifts water. The higher the lift, the
lower the flow.
For parts or assistance, call Master Plumber Customer Service at 1-800-628-9439
15 ft.
20 ft.
No flow at
height shown
below
3,180
1,800
25'
Motor Full Load
Individual Branch
Amps
Circuit Req. (Amps)
7.0
Discharge
Pipe
Basement
Floor
Sump
Pit
6207 0410
the cause of the difficulty. Low voltage, long
extension cords, clogged impeller, very low lift,
a plugged or frozen discharge pipe, etc., can all
cause cycling and overheating.
3. This pump will not remove all the water in the
sump. If you are running the pump manually
and water stops coming out of the discharge,
the pump has probably run dry. Shut it off
immediately and check the water level.
*Switch Setting in inches
Water Level For:
On
15
7-1/2"
Lift
Check Valve
(Install Vertically)
NOTICE The friction caused by water running
through the pipe will also, on longer pipe runs,
reduce the flow. Pipe smaller than the pump
discharge also reduces flow.
5
Off
3"