Loosen the screws.
Press the filter holder upwards and re-
move it.
Remove the lamella filter.
Insert new filter.
Make sure driver engages with holes on
drive side.
Insert the filter holder and press down-
wards.
Tighten the screws.
Note: Make sure when installing the new
filter that the fins are not damaged.
Replacing filter case seal
Lift filter case seal out of groove in the
cover.
Insert new seal.
Check suction blower
Check hose at the suction blower for
tightness.
Checking drive belt
Turn main key to "0" and remove it.
Press emergency-stop button.
Open the device hood.
Check tension of circular belt of the
side-brush; also check for wear or dam-
age.
Check tension, wear and damages on
the V-belt of the sweep roller drive.
Check tension, wear and damages on
the V-belt of the sweep roller drive.
Check tension, wear and damages on
the V-belt of the sweep roller drive.
Tighten the V-belt at the screw if neces-
sary.
10
-
EN
Replacing the fuse
Replace defective fuse.
F 1
F 1 Main fuse
Battery pole fuse
F 2 Automotive flat plug fuse
Vacuum pump
F 5 Automotive flat plug fuse
Beacon light (optional)
Note: This fuse is located un-
derneath the front panel on the
left hand side
Pole fuse
NOTICE
A defective pole fuse may only be replaced
by a Kärcher service technician or an au-
thorised expert. If this fuse is defective,
check the usage conditions and the entire
control system.
Fuse rotating beacon (option)
To replace a fuse, the front panel must be
removed.
Loosen the front panel screws.
Remove front panel.
Replace defective fuse.
F 2
150 A
3 A
7.5 A
25