LED H Voltage.
In all MIG welding processes, indicates that the dis-
play N shows the preset voltage or, in combination with
the lighting of LED F, the actual welding voltage.
In MMA mode it remains lit at all times and cannot be
selected.
Indicates that the display N shows the open-circuit volt-
age or welding voltage or, in combination with LED F lit,
the actual welding voltage.
Knob I.
The following values must be adjusted based
on the type of process:
Welding current A, wire speed
, program number JOB.
In the service functions select the abbreviations: Prc,
TRG, HSA, SP, PrF, PoF, Acc, BB, L, Ito, H2O, Fac. In
synergic programs when one measurement is adjusted,
the others also change as a result. All of these values
are shown on the display M.
Knob L.
The following values must be adjusted based
on the type of process:
In synergic MIG the arc length, in convention-
al MIG the welding voltage.
Based on the symbol set via the knob I, from the service
menu it selects the value set, whether to activate or
deactivate it, or make another choice from within the
function itself.
Display M.
In all welding processes, it numerically
displays the selections made via the
selection key E and adjusted via the
knob I.
For the welding current (LED A) it displays the Amperes.
For the wire speed (LED B) it displays the meters per
minute.
For the thickness (LED C) it displays the millimeters.
For the (LED D) it displays the program number set.
In service functions it displays the abbreviations: Prc,
Sin, (Fac, AF, HS only for MMA mode), TRG, HSA, SP,
PrF, PoF, Acc, bb, L, Ito, H2O, Fac.
For the parameters located within the service functions
that are shown on the display M, see the paragraph ser-
vice functions.
It flashes the message "OPn" if the wire feeder door is
open. In error messages it displays the abbreviation Err.
Display N.
In all welding processes it numerically
displays the arc length in synergic MIG
and the welding voltage in conventional MIG.
For the welding voltage (LED H) it displays the Volts.
For the arc length (LED H) it displays a number between
–9.9 and + 9.9; 0 is the recommended value.
For the parameters located within the MMA service
function that are shown on the display N, see the para-
graph service functions.
For the parameters located within the MIG service func-
tion that are shown on the display N, see the paragraph
service functions.
10
wire speed output from the torch, adjust the knob I.
not pressed again after 30 seconds, the gas output is
interrupted.
, thickness
press the button Q for at least 5 seconds. The LED R
lights, the display M flashes the message STO, and the
display N flashes the first free number. Use the knob L
to choose the number to which to save the previously
chosen pair of current/voltage values.
Press the button Q again until you hear the save confir-
mation sound, and the number stops flashing. Now,
pressing the key Q briefly exits the function and the LED
R shuts off.
To recall a saved number, simply press the button Q
briefly and call up the number using the knob L. You
may save up to 99 pairs of current/voltage values.
To erase a saved number, press the button Q for at least
5 seconds, turn the knob I until the display M shows the
message DEL, and press the button Q again for another
5 seconds.
A current/voltage parameter may be called up beyond
saving, to change or use it. To call up the parameter,
press the button Q for 3 seconds. Use the knob M to
display the number to recall and show on the display M,
using the knob L, the message rcL. Now simply hold
down the button Q for at least 5 seconds.
W – Flow gauge. Its knob adjusts gas flow during
welding.
within the service functions, point 5 Trg).
U - LED. Indicates that two-stage function is active.
T - LED. indicates that four-stage function is active.
SERVICE FUNCTIONS
Press the key V, and hold it down for at least 5 seconds
to enter the submenu. Turn the knob I to select the
function, and use the knob L to select the type of oper-
ation or value.
Button O Wire test.
Allows wire to advance even when no voltage or
current are present. To increase or decrease the
Button P Test Gas.
When this key is pressed, gas begins to flow out;
press it again to stop the output. If the button is
Button Q Saving and calling up saved pro-
grams.
To save a current/voltage parameter, simply
Y - Socket. Socket where to connect the elec-
trode clamp for MMA welding.
S - Selection key. Each brief pressure activates
two-stage or four-stage functions, displayed by
LEDs U and T. (This selection can also be made