Machine Foundation - Alliance Laundry Systems HC18MD2 Instrucciones De Instalación

Montaje fijo en gabinete
Ocultar thumbs Ver también para HC18MD2:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation

Machine Foundation

NOTE: Do not mount on wooden floors, above
ground level, or over basements or crawl spaces
because of the high extract speed and the G-forces
exerted.
The floor must be 3500 psi minimum reinforced
concrete set firmly in clean, compacted fill dirt.
Models
2 Speed and Fixed-Speed
(20-60 Models)
Variable-Speed
(20-60 Models)
Variable-
80 Models
Speed
125 Models
24
Machine Foundation Requirements
Foundation
Floor
Thickness
Thickness
4 in.
4 in.
(102 mm)
(102 mm)
6 in.
6 in.
(152 mm)
(152 mm)
9 in.
6 in.
(229 mm)
(152 mm)
12 in.
6 in.
(304 mm)
(152 mm)
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
The machine must be anchored to a smooth, level
surface so that the entire base of the machine is
supported and rests on the mounting surface. (Do not
support the machine on only four points.)
An elevated foundation must not exceed 8 inches
(203 mm).
Refer to Table 2 for foundation and anchoring
requirements.
Installation
Foundation
Method(s)
Direct-to-finished-floor,
elevated base frame, or
concrete foundation
Direct-to-finished-floor
or concrete foundation
Direct-to-finished-floor
or concrete foundation
Table 2
Anchoring
Anchoring
Bolt
Method(s)
Diameter
Requirement
Size
(minimum)
Expansion bolt
5/8 in.
or J-bolt
J-bolt or
5/8 in.
mounting bolt
J-bolt, mounting
3/4 in.
bolt, or rebar
frame
F232135

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido