Installation
Troubleshooting
If machine fails to operate after power is connected,
proceed as follows:
1. Disconnect power.
2. Unlock and raise top cover.
3. Check circuit fuse.
For mechanical timer, P-computer and
S-computer models, control circuit fuse is located
on center brace.
For EDC and V-computer models, dual control
circuit fuses (one primary, one secondary) are in
control module. A decal identifies fuse(s) and
provides fuse-rating appropriate to that specific
model.
For NetMaster models, circuit fuses are located
on side of control box.
For A-control and B-control models, circuit fuses
are located on the output board.
4. If control circuit fuse has blown, replace with
fuse of appropriate rating as identified by decal.
IMPORTANT: Call a qualified electrician if
replacement fuse blows.
50
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Steam Requirements
(Steam Heat Option Only)
WARNING
Hot Surfaces. Will cause severe burns.
Turn steam off and allow steam pipes,
connections and components to cool
before touching.
For machines equipped with optional steam heat,
install piping in accordance with approved commercial
steam practices. Steam requirements are shown in
Table 17.
Steam Supply Information
Steam inlet
18 – 80 pound
connection size
Number of steam inlets
Recommended pressure
Maximum pressure
Table 17
IMPORTANT: Failure to install the customer
supplied steam filter may void the warranty.
W505
1/2 in. (13 mm)
125 pound
3/4 in. (19 mm)
1
30 – 80 psi
(2.0 – 5.4 bar)
80 psi
(5.4 bar)
F232135