I 1 Max
Max. absorbed current at the corresponding
current I 2 and voltage U 2 .
I 1 eff
This is the maximum value of the actual cur-
ent absorbed, considering the duty cycle.
This value usually corresponds to the capa-
city of the fuse (delayed type) to be used as
a protection for the equipment.
IP23 C.
Protection rating for the housing.
Grade 3 as the second digit means that this
equipment is suitable for use outdoors in the
rain.The additional letter C means that the
equipment is protected against access to
the
live parts of the power circuit by a tool (dia-
meter 2.5 mm ).
S
Suitable for use in high-risk environments.
NOTE: The welding machine has also been designed for use
in environments with a pollution rating of 3. (See IEC 664).
2.1.2 Description of the power source (Fig. 1)
BL
BJ
BA
BB
BI
BO
BP
11
BO - Socket:
In MIG and MMA welding, connect the earth cable con-
nector.
BP - Connector:
Connector type DB9 (RS 232) to be used to update the
microprocessor programs.
BR - Socket:
In MIG welding, connect the patch connector of the
power source/wire feeder connection power cable (pole
+)
BS - Connector
Connect the connector of the power source/wire feeder
connection service cable
BU - Switch ON/OFF.
BV - Power cord.
2.2 WIRE FEEDER
2.2.1 Description of the wire feeder (Fig. 1)
BA - Central adapter:
Connect the MIG welding torch.
BE
BD
BF
BC
BG
BH
BU
BV
BS
BR
BT
BW
BX
BK
Fig. 1
BM
BZ
BY
11