7.3

Sensing range setting

7.4

Time function setting

8020358.1DS8/2021-11-24 | SICK
Subject to change without notice
Table 16: Application conditions
Function reserve
10,000
WSE26P-xxxxx1xx, WSE26I-xxxxx1xx
1,000
100
10
1
0
10
20
30
(0.39)
(0.79)
(1.18)
Figure 12: Characteristic line 1
WSE26x-xxxxxx3xAxx with teach-in button:
There must not be any objects located between the sender and the receiver. The
sensitivity is reduced by pressing the teach-in button (approx. 1-3 seconds). This can
reduce mutual interference between the sensors. The sensing range is also reduced,
and therefore the operating reserve as well. Lead an object into the path of the beam.
The yellow display LED goes out, meaning the object is detected and the setting is
correct.
WEO
1
1...3 sec.
2
Figure 14: WSE26x-xxxxxx3xAxx, adjusting the sensing range with teach-in button
1
1
0
0
Sensing range
Figure 13: Bar graph 1
40
50
60
(1.57)
(1.97)
(2.36)
Distance in m (feet)
WSO
O P E R A T I N G I N S T R U C T I O N S | WSE26
COMMISSIONING
50
60
20
40
60
(65.62)
(131.23)
(196.85)
Distance in m (feet)
Sensing range typ. max.