DIP 2
DIP 2 enables:
- Selection of the PHOTO input operating mode.
- Selection of the operating mode of the "S.S. key" and the transmitter. (S.S.)
- Enable the STOP input as the Pedestrian input (Partial opening) (STOP/PED)
The procedure involves switching DIP 2 ON, carrying out the operations described, then switching it back to OFF to confirm programming.
Selection of the PHOTO input mode
After switching DIP2 On with the PU2 key, the PHOTO input operating mode is set.
The LD2 LED indicates the status of the function:
LED LD2 on:
PHOTO input enabled both in closure and opening.
In the opening phase: opening of the contact caused by stoppage of the motor, when the photocell is free, opening restarts.
In the closure phase: opening of the contact causes stoppage of the motor, when the photocell is free, the running direction
inverts (opens).
LED LD2 off:
PHOTO input enabled only in closure (default).
In the closure phase: opening of the contact causes stoppage of the motor and inversion of the running direction (opens).
ATTENTION: Switch DIP 2 to OFF at the end of programming.
Selection of the operating mode of the "SS key"
After switching DIP2 On with the PU1 key, the SS key and transmitter operating mode is set.
The LD2 LED indicates the status of the function:
LED LD2 on:
OPENS>CLOSES>OPENS> operation
LED LD2 off:
OPENS>STOP>CLOSES>STOP> (default) operation.
ATTENTION: Switch DIP 2 to OFF at the end of programming.
STOP input enabled/disabled as PEDESTRIAN INPUT
After switching DIP2 On, simultaneously pressing PU1+ PU2, the STOP input is enabled or disabled as the input for the PEDESTRIAN command
(becoming a N.O. input)
The LD3 LED indicates the status of the function:
LED LD3 on:
STOP input enabled as the PEDESTRIAN input (N.O.).
LED LD3 off:
No change to the STOP input (default).
ATTENTION: Switch DIP 2 to OFF at the end of programming.
DIP 3
DIP 3 enables:
- Enable/disable the apartment complex function (IBL)
- Enable/disable the impulses block function in the TCA phase (IBCA)
- Enable/disable the rapid closure function (SCL)
The procedure involves switching DIP3 to ON, carrying out the operations described, then switching it back to OFF to confirm programming.
APARTMENT BLOCK FUNCTION (IBL) enabling/disabling
After switching DIP3 On with the PU2 key, the apartment complex function is enabled or disabled (The S.S. or transmitter impulse has no effect
during the opening phase)
The LD1 LED indicates the status of the function:
LED LD1 on:
Apartment complex function enabled.
LED LD1 off:
Sharing function disabled (default).
ATTENTION: Switch DIP 3 to OFF at the end of programming.
Enable the impulses block function in the TCA phase (IBCA)
After switching DIP3 On with the PU1 key, the IBCA function is enabled or disabled (The S.S. or transmitter impulse has no effect during the TCA
pause)
The LD2 LED indicates the status of the function:
LED LD2 on:
IBCA function enabled.
LED LD2 off:
IBCA function disabled (default).
ATTENTION: Switch DIP 3 to OFF at the end of programming.
RAPID CLOSURE (SCL) enabling/disabling
After switching DIP3 On, simultaneously pressing PU1+ PU2 enables or disables rapid closure (with the gate open or in motion, intervention of the
photocell causes automatic closure after 3s. Active only with TCA enabled)
The LD3 LED indicates the status of the function:
LED LD3 on:
Rapid closure enabled.
LED LD3 off:
Rapid closure disabled (default).
ATTENTION: Switch DIP 3 to OFF at the end of programming.
DIP 4
Disabling of the ESA energy saving function.
With the ESA function enabled once opening or closing movements have been completed, the control unit is in maximum energy efficiency condition,
reducing absorption to minimum and disconnecting accessory outputs.
On: ESA energy saving function disabled.
To use if you want to have the accessories power supply output always enabled, for example if using 24 Vdc keypads or other devices that need to be
always powered
Off: ESA energy saving function enabled (default).