| 52 | ACS 611 | Operation
9.3.3
Filling of refrigerant, fresh oil and UV dye
i
Fresh oil and UV dye can only be added to an air
conditioning system under vacuum. A vacuum must
be generated prior to the oil/UV dye filling process.
i
If pressure is detected in the vehicle air
conditioning system during filling, recovery must be
implemented in order to continue.
i
Fresh oil and UV dye can only be added in
conjunction with R134a.
!
Always observe the vehicle manufacturer's
instructions before altering the oil quantity.
!
Before filling with UV dye it is essential to check
whether leak testing of the air conditioning
system with UV dye is approved by the vehicle
manufacturer.
!
Filling should, if possible, only occur via the high
pressure connection. For systems that have only
one low-pressure connection, at least 10 minutes
must pass after filling before the vehicle air
conditioning system can be switched on.
|
1 689 989 600
2020-12-01
<Fill> key
!
Observe the ACS 611 menu prompting.
1. Connect the HP and LP service hoses to the vehicle
air conditioning system.
2. Open the valves on both service hoses.
3. Open the HP and LP valves on the display and
control panel.
4. Call up start screen.
5. Press <Fill>.
SELECT PORTS?
1 HP & LP PORTS
2 HP PORT
3 LP PORT
6. Select <1>,<2> or <3>; confirm with E.
CHARGING UV DYE?
1 - YES
2 - NO
i
The UV contrast medium is added automatically on
a time-controlled basis. The duration, and thus the
quantity, can only be changed by customer service.
7. Select <1> or <2> and confirm with E.
CHARGING OIL?
1 - YES
2 - NO
i
In the case of <1>, the fresh oil quantity must be
entered with <0 – 9> and confirmed with E.
!
The entered quantity is always added, irrespective
of how much oil was previously extracted.
8. Select <1> or <2> and confirm with E.
SET REFRIGERANT CHARGE
9. Enter the refrigerant quantity (R134a) with <0 – 9>
and confirm with E.
"
ACS 611 performs the filling phase.
i
Return with <Stop>.
is displayed.