| 56 | ACS 611 | ACS 611 settings
11.7
UV dye
1. Call up start screen.
2. Press <3> and <Flush> simultaneously and release.
The message
ENTER CODE 0000
2222
and confirm with E.
3. Enter code
4. Select "UV DYE" with o u and confirm with E.
5. Activate or deactivate with o u and confirm with
E.
"
UV dye filling is activated or deactivated.
i
Return with <Stop>.
11.8
Enter serial number
i
The serial number is located on the rating plate on
the back of the housing of ACS 611.
1. Call up start screen.
2. Press <3> and <Flush> simultaneously and release.
The message
ENTER CODE 0000
2222
and confirm with E.
3. Enter code
4. Select "SERIAL NUMBER"" with o u and confirm
with E.
5. Enter serial number with <A – Z>,<0 – 9> and
confirm with E.
"
Serial number is set.
i
Return with <Stop>.
|
1 689 989 600
2020-12-01
11.9
11.9.1
i
is displayed.
ACS 611 can store the R134a consumption data
during all charging and extraction processes.
!
This function can only be activated or deactivated
by customer service.
11.9.2
i
The data storage of ACS 611 may contain more
data than can be printed on one paper roll
(printer).
1. Press <MENU>.
2. Select "REPORT MANAGEMENT" with o u and
confirm with E.
3. Select "PRINT REPORT" with o u and confirm with
E.
The number of saved protocols is displayed.
is displayed.
4. Print all protocols with E .
"
All protocols are printed.
i
Return with <Stop>.
i
We recommend that stored reports are exported,
printed and then deleted at least once a week.
11.9.3
!
All data on the PS2 stick is deleted!
1. Press <MENU>.
2. Select "REPORT MANAGEMENT" with o u and
confirm with E.
3. Select EXPORT DATA with o u and confirm with
E.
4. Insert PS2 stick.
"
All protocols are saved on the PS2 stick.
Service data report
Activate/deactivate consumption
R134a report
Printing data
Exporting data