Qlima SM52 MULTI Manual De Instalación página 69

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 22
nect couplings and in good condition. Before using the recovery machine, check that il is in satisfactory wor-
king order, has been properly maintained and that any associated electrical components are sealed to prevent
ignition in the event of a refrigerant release. Consult manufacturer if in doubt.
The recovered refrigerant shall be returned to the refrigerant supplier in the correct recovery cylinder, and the
relevant Waste Transfer Note arranged. Do not mix refrigerants in recovery units and especially not in cylinders.
lf compressors or compressor oils are to be removed, ensure that they have been evacuated to an acceptable
level to make certain that flammable refrigerant does not remain within the lubricant. The evacuation process
shall be carried out prior to returning the compressor to the suppliers. Only electric healing to the compressor
body shall be employed to accelerate this process. When oil is drained from a system, il shall be carried out
safely.
2.
ITEMS PACKED WITH THE UNIT
Number
Name of Accessories
1
Installation plate
2
Clip Anchor
3
Self-tapping screw 'A' ST 3.9x25
4
Seal
5
Drain joint
6
Connecting pipe
assembly
7
Remote controller
8
Self-tapping screw 'B' ST 2.9x10
9
Remote controller holder
10
Wireless smart kit
G
NOTE!
Except the above provided parts, the other parts needed during installation are to be purchased
separately by the buyer of the air conditioner.
Ø 6.35 (< 6.0 kW model)
Liquid side
Ø 9.53 (> 6.0 kW model)
Ø 9.53 (< 3.5 kW model)
Gas side
Ø 12.7 (≥ 3.5 kW model)
Ø 16.0 (≥ 6.0 kW model)
Quantity
3 x 1
3 x 8
3 x 8
3 x 1
1
Not included
3 x 1
3 x 2
3 x 1
3 x 1
4
69
69

Publicidad

Tabla de contenido
loading

Tabla de contenido