Seal
9.
ELECTRICAL WORK
•
Connect the air conditioner to a separate group. Ensure that this group has the correct fuse
•
See following table.
•
Power voltage supplied should be in the range of 95%~105% of rated voltage on rating table.
•
The power supply must have an earth leak switch installed.
•
Ensure the air conditioner is grounded well.
•
Connect the wires according the attached electrical connection diagram located on the panel of the
outdoor unit. See chapter 11
•
All wiring must comply with local and national electrical standards and codes and be installed by
qualified and skilled people.
Model
SM 52 MULTI
G
NOTE!
The supply voltage should be consistent with the rated voltage of the air conditioner.
10. CONNECTING THE ELECTRICAL CABLES.
a.
Connect the cable to the indoor unit
b.
Indoor/Outdoor connection cable should be H07RN-F type, 2,5 mm².
c.
To mount the cable to the interior unit: Remove the front panel and the cover plate of the terminal
strip on the right hand side of the interior unit. Figure 15.
Front Panel
Front panel
Figure 15
d.
The cable can be fed through from the back of the interior unit to the terminal strip.
e.
Connect the electrical wires to the terminal strip, for the correct location see fig 16.
Drain joint
Base pan hole of
outdoor unit
Seal
Drain pipe
Figure 14
Power supply
230V~ 50Hz
Electronic box
Cover plate
cover
Input Rated Current
(Switch/Fuse)
16A
Power cord size
2,5 mm
2
4
79