Accuracy
Refer to "Specifications" for operating conditions and temperature coefficient.
Accuracy is specified as follows: ± (a percentage of the reading + a fixed amount)
at 23 °C ± 5 °C (73.4 °F ± 9 °F), 0% to 75% relative humidity.
Value
DC Voltage
AC Voltage
AC Current
(200 A range)
AC Current
(600 A range)
Resistance*
* Maximum open circuit voltage: 1 V
Continuity
Threshold: Tone sounds if the measured resistance is less than approximately 50 Ω,
and turns off when greater than approximately 300 Ω.
AC measurements are average sensing, RMS calibrated.
AC accuracy is specified for sine waves only.
Range
0 to 600 V
± (0.8% + 1 V)
0 to 600 V
± (1.2% + 3 V)
0 to 199.9 A
± (1.9% + 0.5 A)
0 to 400 A
± (1.5% + 5 A)
400 to 600 A
± (2.5% + 5 A)
0 to 2000 Ω
± (1.5% + 2 Ω)
Frequency
Accuracy
40 to 500 Hz
Range
Impedance
N/A
50/60 Hz
50/60 Hz
50/60 Hz
N/A
CM-600
Input
2 MΩ
2 MΩ
2 nF
N/A
N/A
N/A