English
Error messages
DANGER! Electric shock!
▶ Before clearing faults, remove the mains plug and the switching power supply unit.
Message
Possible cause
P1
Water temperature sensor is defective
P2
Temperature sensor for the overheating protection is
defective
HA
Water temperature is above the set target temperature
HA2
Air filter and/or ventilation grille dirty
(Overheating)
Ambient temperature too high
Ventilation system damaged
LA
Water temperature is below the set target temperature
For other faults, please contact EHEIM Service.
Technical data
climacontrol+
Type
Aquarium size up to
Mains voltage/frequency
Power consumption (cooling mode)
Cooling output: *
Water temperature 25°C
1
Water temperature 12°C
2
Noise level / 80 cm (cooling mode)
Power consumption (heating mode)
Heating output Δt**
Hose connection for hose Ø
Water flow
System pressure
Weight
Dimensions (L × W × H)
Switching power supply unit
Type
Plug
Input
Output
*
= value calculation: 1× Aquarium with cover, room temperature 30°C, thermal load
Model S and M = 0.3 W/l, Model L = 0.2 W/l,
1
= 0.1 W/l
2
** = value calculation 1× Aquarium with cover, room temperature 20°C,
Δt = temperature difference: room temperature to water temperature
Spare parts
See page 3.
S
3750
500 l
260 W (230 V)
max.
500 l
max.
200 l
~47 – 50 dB
~15°C
IN
OUT
min.
max.
max.
17.0 kg
310 × 310 × 447 mm
Remedy
▶ Contact the EHEIM customer service: www.eheim.com
▶ Contact the EHEIM customer service: www.eheim.com
▶ Check whether the aquarium filter or the pump are working
▶ Check the hose installation for bends or constrictions.
▶ Clean the aquarium filter and/or pump
▶ Clean the piping
▶ Check if the cooling function is switched on
▶ Clean the air filter
▶ Make sure that the device is operated in an ambient temperature of
no more than +38°C.
▶ Contact the EHEIM customer service: www.eheim.com
▶ Check whether the aquarium filter or the pump are working
▶ Check the hose installation for bends or constrictions.
▶ Clean the aquarium filter and/or pump
▶ Clean the piping
▶ Check if the heating function is switched on
M
3751
1000 l
230 V / 50 Hz
300 W (230 V)
1000 l
300 l
~50 – 53 dB
300 W
~10°C
Ø 16/22 mm / with reducing coupling 19/27 mm
500 l/h
800 l/h
1 bar / 14.4 psi
18.7 kg
310 × 310 × 489 mm
7341218
EUR
100 – 240 V / 50/60 Hz / 0.4 A
5 V DC / 1 A / 5 W
15
L
3752
2000 l
400 W (230 V)
2000 l
500 l
~51 – 54 dB
~6°C
19.7 kg
310 × 310 × 531 mm