Operating The Machine; Machine Features; Assembling And Adjustment; Assembling The Parts Cleaning Device - IBS M Manual Del Usuario

Ocultar thumbs Ver también para M:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 34

6. Operating the Machine _______________________________

6.1. Machine Features

Use the foot-operated safety switch to turn the machine on.

6.2. Assembling and Adjustment

6.2.1. Assembling the parts cleaning device

• Remove all packaging materials.
• Insert the two base legs (1) into the round pipe sleeves (2) underneath the basin.
• Secure each of the two cross braces (3) to the base legs (4) using the hexagonal head cap
screws provided.
• Place the 200-litre drum (5) into the catch basin (6) with the threaded joint facing upwards,
and remove the cover plug joint from the drum.
• Place the assembled unit above the drum (5).

6.2.2. Assembling the pump

• Tilt the drum (5) slightly, guide the self-priming pump into the drum, and thread the pump
into the 2" thread plug (8). Make sure that the outgoing lines for the pump (12) face to the
left.
• Insert the return hose (9) into the opening of the 2" thread plug (8).
• Secure the top end of the return hose (9) to the basin's drain connection piece (10).
• Attach the brush hose (11) to the pump (12).
• Guide the brush hose (11) through the round back wall opening of the basin (13) and insert
the cleaning brush (14) into the hose.
• Place the safety foot switch (7) in front of the unit.
• Plug the plug (15) into the 230 V-outlet.
• Perform a function test

6.2.3. Startup

• Place the workpiece you intend to clean onto the support grate.
• Step on the foot pedal switch to turn the unit on.
• Use the brush to clean the workpiece.
• Release the foot switch to turn the pump off.
Operating Instructions Parts Cleaner Type M/MD (02/2010/EN)
complete
pump
Page
7

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Md

Tabla de contenido