In-Place Sanitization - Bras B 3 Manual De Instrucciones

Ocultar thumbs Ver también para B 3:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

EN GLIS H
B 3
4
Fit bowl gasket around its seat.
Note: the largest brim of gasket must face
against the rear wall (see figure 12).
figure 12
5
Insert the magnetic outside rotor in the
evaporator taking care to accompany it to the
end (see figure 13).
figure 13
6
Install the outer spiral. Slide it over the
evaporator until its hexagonal front notch
engages with the hexagonal exposed end of the
magnetic outside rotor (see figure 14).
7
Push the bowl towards the rear wall of the
unit until it fits snugly around the gasket and its
front fastening hooks are properly engaged (see
figure 15).
8
Use fresh product to chase any remaining
sanitizer from the bottom of the bowl(s). Drain
this solution. Do not rinse out the machine.

7. 4 IN-PLACE SANITIZATION

The In-Place Sanitization prior to starting the
machine may be performed, if needed, only as
f u r t h e r p r e c a u t i o n , i n a d d i t i o n t o t h e
Disassembled Parts Sanitization described
before, but never in lieu of it.
1
Prepare two gallons of a warm (45-60°C,
120-140 °F) sanitizing solution (100 PPM
available chlorine concentration or 1 spoon of
sodium hypoclorite diluted with 2 liters of water)
20
figure 14
figure 15